Engine Starts Hard And Runs Rough; Engine Starts Then Shuts Down - Generac Power Systems 4451 & 4986 Repair Manual

Ultra source portable generator
Table of Contents

Advertisement

section 5
tRoublesHooting FloWcHaRts
CHECK
FUEL
GOOD
SUPPLY
LOW FUEL
PUSH IN AFTER STARTING
REPLENISH
FUEL
SUPPLY
TEST 38 -
CHECK
GOOD
FUEL PUMP
BAD
REPAIR
OR REPLACE
TEST 41 - CHECK
ENGINE /
CYLINDER LEAK
DOWN TEST /
COMPRESSION
TEST
CHECK
ENGINE OIL
OIL LEVEL O.K.
LEVEL
OIL LEVEL LOW
REPLENISH OIL
GO TO PROBLEM 8
Page 34
Problem 8 - Engine Starts Hard and Runs Rough
CHECK CHOKE
POSITION AND
GOOD
OPERATION
TEST 39 - CHECK
GOOD
CARBURETION
BAD
REPAIR
OR REPLACE
FLYWHEEL KEY -
GOOD
BAD
Problem 9 - Engine Starts Then Shuts Down
TEST 42 - CHECK OIL
PRESSURE SWITCH
AND WIRE 86
REPLACE SWITCH
VERIFY START STOP RELAY (SSR)
TEST 29 -
GOOD
CHECK
SPARK
ENGINE MISS
IS APPARENT
TEST 35 - CHECK AND
ADJUST IGNITION
MAGNETOS
TEST 5 - CHECK
STEPPER
MOTOR
CONTROL
BAD
REPAIR
OR REPLACE
CHECK
SEE TEST 35
REPAIR OR REPLACE AS NECESSARY
REFER TO ENGINE SERVICE MANUAL P/N
0E2081 FOR FURTHER ENGINE SERVICE
GOOD
BAD
IS WIRED PROPERLY
TEST 30 -
CHECK
GOOD
SPARK
PLUG
BAD
REPLACE SPARK PLUG
ADJUST
BAD
OR REPLACE
TEST 40 - CHECK
GOOD
VALVE
ADJUSTMENT
BAD
ADJUST VALVES
AND RETEST
INFORMATION
TEST 27 - TEST
START-RUN-STOP
SWITCH (SW1)
BAD
REPLACE SWITCH
GOOD

Advertisement

Table of Contents
loading