White Rodgers Electro-Air 10C27S-010 Owner's Manual

White Rodgers Electro-Air 10C27S-010 Owner's Manual

Electronic air cleaner super slim twin & universal slim twin 240 volt 50/60 hz

Advertisement

Electronic Air Cleaner
240 Volt 50/60 Hz
SST
Super Slim Twin
Model Number
10C27S-010
14C27S-010
20C27S-010
UST
Universal Slim Twin
Model Number
16C27S-010
Please read and familiarize yourself with the contents of this manual
before installing, operating or performing maintenance on the unit.
UL Listed
CSA Certified
OWNERS MANUAL
Installation
Operation
Basic SST/UST Service Guide
Technical Repair Guide
Repair Parts
Printed In U.S.A.
by White-Rodgers
Part No. 37-6123D
Replaces 37-6123C
DG ERS
WH ITE -RO
0032

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Electro-Air 10C27S-010 and is the answer not in the manual?

Questions and answers

Summary of Contents for White Rodgers Electro-Air 10C27S-010

  • Page 1 White-Rodgers Electronic Air Cleaner 240 Volt 50/60 Hz Super Slim Twin DG ERS WH ITE -RO Model Number 10C27S-010 14C27S-010 20C27S-010 Universal Slim Twin OWNERS MANUAL Model Number Installation • 16C27S-010 Operation • Basic SST/UST Service Guide • Technical Repair Guide •...
  • Page 2: Table Of Contents

    Rules for Safe Installation and Operation ..2 How the Air Cleaner Works ......3 Model 10C27S-010 is designed for heating or cooling blowers delivering 600 to 1200 cubic feet of air per minute Construction of the Air Cleaner....... 3 (cfm.)
  • Page 3: How The Air Cleaner Works

    HOW THE AIR CLEANER WORKS Dirt particles flowing through the ducts (Figure 1) first enters the pre-filters (A) where large particles (hair, lint, Dirty Air In Clean Air Out etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through these pre-filters and enter the ionizing section (B).
  • Page 4: Preinstallation

    If your furnace duct system has a pre-installed boot, MODEL NO. discard front cover of boot and slide the air cleaner 10C27S-010 24 3/4 21 5/16 18 5/8 13 9/16 16 7/16 19 1/16 component inside the boot. (Applies to 14C27S-010 and 14C27S-010 29 11/16 26 1/4 23 5/8 13 9/16 16 7/16 19 1/16 20C27S-010.)
  • Page 5 TYPICAL MOUNTING POSITIONS Air Flow Air Flow Air Flow Rear View Rear View Figure 6 Figure 8 Figure 7 BASEMENT FURNACE HIGHBOY FURNACE (LOWBOY) (Figure 6) (Figure 8) COUNTERFLOW FURNACE (Figure 7) Cleaner is mounted hori- Side installation. Cleaner zontally in return plenum, is mounted vertically, Cleaner is mounted horizon- just above furnace.
  • Page 6: Installation

    INSTALLATION REMOVE OLD FILTER AND DISCARD (Figure 12) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT Figure 12 It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation.
  • Page 7: Wiring Instructions

    WIRING INSTRUCTIONS CAUTION 7. With the cabinet installed, the air cleaner can now be Electrical power to the furnace should be turned wired to electrical input source. off or disconnected at the circuit breaker. WARNING 8. The air cleaner must be wired through the furnace controls to a 240 VAC 60 Hz electrical source.
  • Page 8: Operation

    9. Remove junction box cover and install the required bushing into the 3/4 in. Knock out. With the supply voltage turned off, route three (3) wires into junction box for connections. (See Fig. 19.) Insure all wires are clamped, wire connectors prop- Grounding erly installed and grommets used to prevent wire Conductor...
  • Page 9: Maintenance And Washing

    A moderate amount of arcing or “snapping” may MAINTENANCE AND occur at this time, which will indicate that the cell(s) WASHING are still damp. If the noise is objectionable, push the ON-OFF switch to the “OFF” position and allow additional time for cell(s) and pre-filter(s) to dry. In CAUTION some cases the Operating Light will remain OFF during this initial activation of the air cleaner, and this...
  • Page 10: Specifications

    SPECIFICATIONS SPECIFICATIONS 10C27S-010 14C27S-010 16C27S-010 20C27S-010 Rated Capacity 600 - 1200 cfm 1000 - 1600 cfm 1000 - 2000 cfm 1600 - 2200 cfm Max. Pressure Drop .08 in. W.G. .08 in. W.G. .12 in. W.G. .09 in. W.G. Cell Weight (2) 7 lbs.
  • Page 11: Technical Repair Guide

    TECHNICAL REPAIR GUIDE All voltage measurements indicated can be made with a WARNING high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent. Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, NOTE: All tests to be performed with the Ozone Reduc- utility connections and potential hazards.
  • Page 12 POWER SUPPLY OZONE REDUCTION CHECKOUT PROCEDURE All electronic air cleaners typically produce a small amount of ozone that is within established limits. Some customers 1. Turn power switch to the “OFF” position and remove may notice an odor especially at high altitudes or low air the power pack from cabinet.
  • Page 13 NOTES...
  • Page 14: Repair Parts

    REPAIR PARTS...
  • Page 15 2. The PART DESCRIPTION 3. The MODEL NUMBER 4. The NAME OF ITEM - Electronic Air Cleaner. Always order by “PART NUMBER” . . . Not by “ITEM NUMBER” PART NUMBER ITEM DESCRIPTION 10C27S-010 14C27S-010 16C27S-010 20C27S-010 Cabinet Pre-Filter • F825-0431 •...
  • Page 16 NOTICE TO CONSUMERS White-Rodgers Electronic Air Cleaner Dear Consumer; White-Rodgers would like to thank you for purchasing a White-Rodgers Electronic Air Cleaner or product containing a White-Rodgers Electronic Air Cleaner. Although White- Rodgers does not extend a warranty directly to consumers, White-Rodgers does extend a warranty to Wholesalers and Original Equipment Manufacturers who use White-Rodgers Products.