Summary of Contents for White Rodgers electro-air SST10C27S-010
Page 1
This Owner's Manual is provided and hosted by Appliance Factory Parts. WHITE RODGERS SST20C27S-010 Owner's Manual Shop genuine replacement parts for WHITE RODGERS SST20C27S-010 Find Your WHITE RODGERS Air Cleaner Parts - Select From 61 Models -------- Manual continues below --------...
Page 2
by White-Rodgers Electronic Air Cleaner 240 Volt 50/60 Hz Super Slim Twin DG ERS WH ITE -RO Model Number 10C27S-010 14C27S-010 20C27S-010 Universal Slim Twin OWNERS MANUAL Model Number Installation • 16C27S-010 Operation • Basic SST/UST Service Guide • Technical Repair Guide •...
1. Read the Owners Manual and the Rules for Safe RULES FOR SAFE Operation carefully. Failure to follow these rules and INSTALLATION instructions could cause a malfunction of filter or unsatisfactory service. AND OPERATION 2. Follow a regular service and maintenance schedule for efficient operation.
HOW THE AIR CLEANER WORKS Dirt particles flowing through the ducts (Figure 1) first enters the pre-filters (A) where large particles (hair, lint, Dirty Air In Clean Air Out etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through these pre-filters and enter the ionizing section (B).
PREINSTALLATION Not to Exceed 20° (Interchangeable) (Interchangeable) Collecting Cell Air Flow Collecting Cell Outlet Box Cabinet Power Pack Handle Air Flow Furnace Opening Electronic Air Cleaner Contact Opening Button Contact Furnace Electronic Pre-Filters Button Transition Section Air Cleaner (Interchangeable) See text for Cell (if Needed) Removal Clearance Figure 4...
Page 6
TYPICAL MOUNTING POSITIONS Air Flow Air Flow Air Flow Rear View Rear View Figure 6 Figure 8 Figure 7 BASEMENT FURNACE HIGHBOY FURNACE (LOWBOY) (Figure 6) (Figure 8) COUNTERFLOW FURNACE (Figure 7) Cleaner is mounted hori- Side installation. Cleaner zontally in return plenum, is mounted vertically, Cleaner is mounted horizon- just above furnace.
INSTALLATION REMOVE OLD FILTER AND DISCARD (Figure 12) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT Figure 12 It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation.
WIRING INSTRUCTIONS CAUTION 7. With the cabinet installed, the air cleaner can now be Electrical power to the furnace should be turned wired to electrical input source. off or disconnected at the circuit breaker. WARNING 8. The air cleaner must be wired through the furnace controls to a 240 VAC 60 Hz electrical source.
9. Remove junction box cover and install the required bushing into the 3/4 in. Knock out. With the supply voltage turned off, route three (3) wires into junction box for connections. (See Fig. 19.) Insure all wires are clamped, wire connectors prop- Grounding erly installed and grommets used to prevent wire Conductor...
A moderate amount of arcing or “snapping” may MAINTENANCE AND occur at this time, which will indicate that the cell(s) WASHING are still damp. If the noise is objectionable, push the ON-OFF switch to the “OFF” position and allow additional time for cell(s) and pre-filter(s) to dry. In CAUTION some cases the Operating Light will remain OFF during this initial activation of the air cleaner, and this...
TECHNICAL REPAIR GUIDE All voltage measurements indicated can be made with a WARNING high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent. Do not attempt installation of this unit unless you are familiar with the necessary tools, equipment, NOTE: All tests to be performed with the Ozone Reduc- utility connections and potential hazards.
Page 13
POWER SUPPLY OZONE REDUCTION CHECKOUT PROCEDURE All electronic air cleaners typically produce a small amount of ozone that is within established limits. Some customers 1. Turn power switch to the “OFF” position and remove may notice an odor especially at high altitudes or low air the power pack from cabinet.
Page 16
REPAIR PARTS PARTS LIST FOR ELECTRONIC AIR CLEANERS When ordering repair parts, always give the following information as shown in this list. 1. The PART NUMBER 2. The PART DESCRIPTION 3. The MODEL NUMBER 4. The NAME OF ITEM - Electronic Air Cleaner. Always order by “PART NUMBER”...
Page 17
NOTICE TO CONSUMERS White-Rodgers Electronic Air Cleaner Dear Consumer; White-Rodgers would like to thank you for purchasing a White-Rodgers Electronic Air Cleaner or product containing a White-Rodgers Electronic Air Cleaner. Although White- Rodgers does not extend a warranty directly to consumers, White-Rodgers does extend a warranty to Wholesalers and Original Equipment Manufacturers who use White-Rodgers Products.