Page 1
Electronic Air Cleaner Model Number CSC1000 Please read and familiarize yourself with the contents of this manual before installing, operating or performing maintenance on the unit. White-Rodgers is a division of Emerson Electric Co. www.white-rodgers.com OWNER’S MANUAL • Installation • Operation •...
Installation should be performed only by a qualified service provider. Failure to do so could result in reduced performance of the unit, serious personal injury or death. CSC1000 Self-Contained Ceiling Hung Electronic Air Cleaner Model: CSC1000 Voltage: 120 VAC, 60 Hz. Watts HI-speed: 240 Fan Speed: Variable 200 to 1000 CFM ”D...
Clean Air Out INSTALLATION PLACEMENT The installer must be qualified to make approved electrical connections and a safe ceiling installation with attention to the best placement as shown in the following drawings. The electronic air cleaner should be mounted on the ceiling near the center of the room.
WIRING INSTRUCTIONS Standard electrical wiring of 120 volts, 60 Hz, 15 Amp circuit is adequate. Local residential and commercial wiring codes shall apply. Flexible conduit should be used (Fig. 5). OPERATION/MAINTENANCE OPERATION 1. With the 120 VAC power turned on, adjust the knob to the position desired.
TECHNICAL REPAIR GUIDE WARNING Do not attempt repair of this unit unless you are familiar with the necessary tools, equipment, utility connections and potential hazards. Repair should be performed only by a qualified service provider. Failure to do so could result in reduced performance of the unit, serious personal injury or death.
This power supply has a “hairpin” shaped jumper wire labeled W1 that can be cut and separated in case of such complaints. This will cause the power supply to limit the maximum operating power to a lower level. CSC1000 WIRING DIAGRAM WHT/BRN LINE...
Page 7
†† Not Shown DESCRIPTION Pre-Filter Collecting Cell Power Supply † Switch, Safety Switch, Variable Speed Fan Motor Fan Blade Charcoal Filter Light Knob Ionizing Wire †† Manual CSC1000 F825-0357 F811-0414 F858-1002 F876-0199 F876-0203 F849-0060 F848-0315 F825-0460 F844-0143 F839-0019 F843-0500 37-6336...
WASH REMINDER SCHEDULE A regular washing schedule is necessary to ensure proper efficiency. A thorough washing once every month will be ad- equate for most installations. More or Less Year FEB MAR APR MAY JUN 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___...