Error Codes
When an error has occurred, "ERROR #" will appear on the text display alternating with the message
"OUT OF ORDER."
NOTE: Log number will show in the Incline Display as L-01 through L-20.
Press CLEAR button and hold to clear all errors in log. The display reads "NO ERRORS" when log is empty.
Press enter to exit out.
NOTE: See contact information in Chapter 5 – Customer Service for all maintenance and service activities.
Incline and low battery errors are as follows:
Error Number Cause
24: Incline
Incline is commanded to move,
moving
yet the change in feedback
too slowly
is slower than the minimum
allowed.
25: Incline
Incline is commanded to move
movement
yet the feedback indicates the
feedback
value is not changing or ceases
stopped
to change as expected.
26: Incline
Incline feedback problems could
disabled
not be remedied by
re-calibrating after an Error 25.
27: Low
Battery voltage is reported to be
Battery
below the limit of 10.7v DC and
the controller has issued the low
battery warning.
Cybex Arc Trainer 750A/750AT Owner's Manual
Display
None, stored error only
Dashes shown in incline
window.
Dashes shown in incline
window. Incline is
disabled.
Dashes shown in incline
window. Incline is
disabled.
Reset/Remedy
•
Inspect and lubricate the
lead screw.
•
Re-calibrate the incline.
Measure the incline
•
potentiometer output.
The potentiometer
could be 'bad'.
•
Replace the battery.
Display attempts to
re-calibrate incline position
on entry to Dormant Mode.
Contact service technician.
Further use will re-charge
the battery and the error
condition will be cleared
automatically.
Maintenance
Page 4-5
Need help?