3. Troubleshooting
Problem
WEISSCAM HS-2 does not start
No image or faulty image at the
HD-SDI LINK A / LINK B
●
Cause
>>
possible solution
●
No power source connected
>>
Connect power source
Power source must supply the correct
voltage (12 - 24V DC), above all for bat-
tery operation
>>
Replace battery
●
Cable defective or incorrect pin assign-
ment
>>
Check / replace cable
●
Turn-on pulse not received correctly
>>
Turn the WEISSCAM HS-2 off and back
on again
●
Debayerboard started incorrectly
>>
Turn the WEISSCAM HS-2 off and
back on again
●
Respective port defective
>>
Plug the BNC cable into the second
HD-SDI port (single link)
●
BNC cable defective
>>
Replace BNC cable
●
Target device defective or incompatible
>>
Connect to another target device
(e.g. monitor)
●
Signal transmission on the BNC cable
disrupted by another cable
>>
Check the cable routing and bypass
possible sources of interference
3