Control Panel; Quickstart Operating Instructions; Volume Control And On/Off Switch - Minelab Sovereign GT User Manual

Table of Contents

Advertisement

7. control panel

www.minelab.com
7. Control Panel
This section gives detailed
descriptions of the Sovereign
GT's controls and functionality.
It is important that this section is
read carefully as it will provide
all the information required to
set and adjust these controls.
It may be beneficial to refer back
to this section in the future.
Figure 11 - The Sovereign GT
Control Panel
7.

Quickstart Operating Instructions

1.
To start detecting as soon as possible, here are some Quickstart settings that you can use.
Quick Operating Instructions
Disc Mode
a) Install charged batteries.
b) Set the Mode switch to Disc. Iron Mask /OFF.
c) Set the Ground Balance switch to Pinpoint.
d) Turn the Sovereign GT On by turning the Volume control to approximately 3-o'clock.
e) Set the Threshold / Silent search switch to Threshold.
f) Turn the Threshold control in a clockwise direction until the tone becomes "just" audible.
g) Set the Sensitivity control to Auto.
h) Set the Disc control to the 3rd dot.
i) Set the Notch control to zero until you better understand its appropriate settings.
j) You can now start searching.
p12
7. control panel
All Metals Mode
a) Install charged battery pack.
b) Set the Mode switch to All Metals.
c) Turn the Sovereign GT On by turning the Volume control to about 3-o'clock.
d) Turn the Threshold control in a clockwise direction until the tone becomes "just" audible.
e) Set the Sensitivity control to Auto .
f) Put the Ground Balance switch into Track and ground balance the detector by raising and
lowering the coil from 2 – 15cm above the ground until the threshold becomes stable.
Note: : Disc. and Notch controls are disabled when the detector is in the All Metal mode.
Once you are familiar with all of the controls, you will gain greater performance and
versatility by setting the controls to suit the needs of the area being detected.
7.

Volume Control and On/Off Switch

2.
This control, located at the bottom left of the control panel, is used to adjust a target's signal
volume in addition to switching the Sovereign GT On or Off.
When in the fully anti-clockwise position, the Sovereign GT is turned Off. Turning the control
clockwise, will "click" the Sovereign GT On. Continuing to turn this control in a clockwise
direction will increase the volume of the target signals. At the most clockwise position, the volume
will be set at the "maximum" position. Minelab recommends this position for most circumstances.
However users should be aware that when using headphones, if a large target is detected close
to the surface, the resulting loud signal may cause some hearing discomfort; in areas like this a
lower volume should be selected.