7. The machine should be stopped if the operating situation is against the following points.
Otherwise, the machine will be easily damaged:
+ The fluctuating scope of voltage cannot be over +/-10% of the rating voltage.
+ The interval of each operation cannot be less than 5 minutes, otherwise, it would cause
damage to compressor. Moreover, operation times cannot be more than 6 times per hour.
8. The dehumidifier has time-delay protection
9. Even in a satisfied working environment, humidity's setting value should be a little bit
higher.
10. Make sure that the setting of the whole machine should be stable and there is no
other big obstruction around the machine
11. The machine should be far from heat sources, inflammable and explosive gases.
12. Try to be far away from dusty environment, or the place where it is polluted seriously
by acid-alkali chemical.
13. For three phases machine set, you should be sure that the running direction of fan is
correct. (The running direction of fan wheel points to machine's fron face).
14. Adjust humidity controller, set one required humidity value.
15. Press ON button to start Fan
16. The compressor will start after 3 minutes' time delay
17. When the machine just start or surrounding temperature is low, the red lamp will turn
on. This situation is normal.
18. When humidity reduces to the setting value, dehumidifier's compressor will stop (when
temperature increases, it will restart).
19. Drain pipe can connect with other pipe to drain the water out.
20. Before using, you should pay attention to check whether electricity power is suitable
for machine's power requirement.
21. The electricity parts should be far away from rain or water with the purpose to avoide
electric leakage. If the above situation happens, you should have some dry treatment.
22. You should clean the surface periodically. But decontamination reagent or other
organic solvent to clean it.
23. The Air Filter for inlet air should be cleaned once a week. If surrounding environment
is much dusty, the cleaning time should be shorter.
24. When the machine is moved to another place, the machine should be with vertical
position. If it need to lean, the angle with the horizon should be less than 45 degree.