USER'S MANUAL
Model: ID-3750
Standard type
©
IKENO DEHUMIDIFIER

Advertisement

Table of Contents
loading

Summary of Contents for Ikeno Dehumidifier ID-3750

  • Page 1 USER’S MANUAL Model: ID-3750 Standard type © IKENO DEHUMIDIFIER...
  • Page 2: Table Of Contents

    - 1 - CONTENTS Page I. GENERAL INFORMATION II. PRODUCT DESCRIPTION 1. MAIN FEATURES 2. COMPONENT IDENTIFICATION 3. WORKING PRINCIPLE 4. DIMENSION 5. SPECIFICATION 6. MOISTURE REMOVAL CAPACITY 7. ELECTRICAL DIAGRAM III. INSTALLATION 1. RECEIVING INSPECTION 2. WORKING ENVIRONMENT 3. POWER SOURCE 4.
  • Page 3: General Information

    I. GENERAL INFORMATION Ikeno dehumidifiers provide an effective and efficient solution to humidity control. Ikeno high temperature type dehumidifiers, ID-3750, are designed for airflow of 3000CMH and easily installation. Moreover, the units are designed for duct installation so that there are more option for system installation.
  • Page 4: Component Identification

    - 3 - The unit can be installed conveniently. The conventional type and the wall hanging type • can be installed on anyplace in the room and can be used after being powered. The unit installed outside must be covered under shield to avoid sunlight and rain. The wall hanging type is suitable for the narrow place needing be dehumidified for its •...
  • Page 5: Dimension

    - 4 - send the defrosting command automatically as the situation. After defrosting, the dehumidifier will turn back to run normally. In order to protect the unit from severe damage during operation the unit is equipped with such a safety features such as: low pressure cut-off, compressor overload protection, defrost cycle, main short-circuit fuse.
  • Page 6: Specification

    - 5 - 5. SPECIFICATION STANDARD MODEL Type ID-3750 Capacity L/h Flow m3/h 3000 Power Kw Note : Nominal working condition : 27.0 C ( DB ), 21.2 C ( WB ) Low temperature working condition : 5.0 C ( DB ), 2.1...
  • Page 7: Electrical Diagram

    - 6 - 7. ELECTRICAL DIAGRAM LTP: Low pressure switch COMP: Compressor HTP: High pressure switch TR1: Time relay (3 min) MC1: Main insulator & coil TR2: Time relay (30 min) FU: Fuse IKENO INDUSTRIAL DEHUMIDIFIER - USER'S MANUAL - Model ID-series Subject to change without prior notice...
  • Page 8: Installation

    - 7 - III. INSTALLATION 1. Receiving inspection Remove the shipment packing and inspect unit to ensure that no damage has occurred during transportation and storage. Any visible damage must be reported to nearest Ikeno representative. 2. Working Environment + The unit should be installed stably. There should be one meter of space in front of the inflow and outflow.
  • Page 9: Troubles And Countermeasurements

    - 8 - 1. Clean the air filter When cleaning, gently tap the air filter or remove the dust with a vacuum cleaner, or you can put the air filter in warm water ( ≤ 40 C, add a little neutral detergent ) to wash it or to brush it, and then wash with clear water.
  • Page 10 - 9 - 7. The machine should be stopped if the operating situation is against the following points. Otherwise, the machine will be easily damaged: + The fluctuating scope of voltage cannot be over +/-10% of the rating voltage. + The interval of each operation cannot be less than 5 minutes, otherwise, it would cause damage to compressor.
  • Page 11 Conformity with directives and standards The Ikeno dehumidifier is designed and manufactured by an EN-ISO 9001 accredited development and manufacturing organization. The unit conforms with the specifications in the Machinery Directive 98/37/EEC, the Low Voltage Directive 73/23/EEC as amended by Directive 93/68/EEC and the EMC Directive 89/336/EEC as amended by Directives 92/31/EEC and 93/68/EEC.
  • Page 12 ไทย) Assembled in Thailand...