Using Coaxial Communications - Samsung SCO-3080R Series User Manual

High resolution weatherproof ir camera
Hide thumbs Also See for SCO-3080R Series:
Table of Contents

Advertisement

Connection
(1) Connection to a PC.
Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.
EX) SERIAL PORT OF THE PC(COM1)
RS-485 CONTROL CABLE
(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.
485 Control Board Connection Port
RS-485 Communication establishment initial value.
Item
Initial value
When making a control system to control the camera, please use to the protocol SAMSUNG-T,
SAMSUNG-E, PELCO-D , PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, AD, GE.
When you connecting to RS-485 CONTROL TERMINAL, please peel off the outer skin inside the
RS-485 CONTROL TERMINAL.
Motion detection signals are output through this terminal.
MD - OUT:
GND:
Used for earth-grounding.

USING COAXIAL COMMUNICATIONS

• Coaxial Communications System
• OSD Control method
• If you set the sensitivity level of the sub menu item (of COAX) to "Low", you have to
press the MENU/ENTER (OSD KEY) button twice in a row to access the OSD menu.
(To prevent an error by noise from the DVR)
CAMERA
SET
UP
DOWN
LEFT
RIGHT
16_ Connection
(+) CONNECTION TERMINAL
(-) CONNECTION TERMINAL
Camera ID
1
SERIAL CABLE
BAUD RATE
UART MODE
9600
8-NONE-1
DVR
MENU/ENTER
UP KEY
DOWN KEY
LEFT KEY
RIGHT KEY
RS-485 CONVERTER
RS-485 Control Port
(TRX+)
(TRX-)
RET PKT
ENABLE
CONTROLLER
OSD KEY
JOYSTICK UP
JOYSTICK DOWN
JOYSTICK LEFT
JOYSTICK RIGHT