Download Print this page

Whirlpool AKT 424 Installation page 4

Built-in gas hob

Advertisement

PRATICAL ADVICE FOR USING THE BURNERS
This hob has burners of different diameters. For better burner
performance, please stick to the following rules:
-
Use pots and pans with bottoms the same width as that of the
burners or slightly larger (see table on the right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and keep the
pot covered.
-
Make sure pots on the grates do not protrude beyond the edge of
the hob.
-
In the case of pans with convex bottoms (WOK), use the support grille
provided, which should be positioned only on the 4 ring burner.
IMPORTANT: improper use of the grids can result in damage to the hob:
do not position the grids upside down or slide them across the hob.
Do not use:
-
Cast iron griddles, ollar stones, terracotta pots and pans.
-
Heat diffusers such as metal mesh, or any other types.
-
Two burners simultaneously for one receptacle (e.g. fish kettle).
HOW TO USE THE HOB
Do not let the burner flame extend beyond the edge of the pan.
WARNING
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because
of sudden draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain
lit, wait at least one minute before trying to light it again.
NOTE: should particular local conditions of the delivered gas make the ignition of burner difficult, it is
advisable to repeat the operation with the knob turned to small flame setting.
The burner might go out when the knob is released.
enough. In this case, repeat the operations described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: in case of installation of a hood above the cooktop, please
refer to the hood instructions for the correct distance.
Burner
Ultra-rapid
From 24 to 26 cm
Semi-rapid
From 16 to 22 cm
Auxiliary
This means that the safety device has not warmed up
INJECTORS TABLE
Type of gas used
Pot Ø
From 8 to 14 cm
NATURAL GAS
Ultra-rapid
G20
(Methane)
Semi-rapid
Auxiliary
LIQUEFIED
Ultra-rapid
PETROLEUM GAS
Semi-rapid
(Butane) G30/G31
Auxiliary
Type of gas used
G20 20 mbar
G30/G31 37 mbar
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of
Injector
Rated
Rated
burner
marking
thermal
consumption
flow rate
kW
144 B
3.50
333 l/h
97
1.65
157 l/h
74 B
1.00
95 l/h
94
3.50
254 g/h
65
1.65
120 g/h
50
1.00
73 g/h
Model
Rated thermal flow rate
configuration
(kW)
4 burners
7.80
4 burners
7.80
CATEGORY II2H3B/P
Reduced
Gas pressure
heat
mbar
capacity
kW
min.
rat.
max.
0.60
0.35
17
20
25
0.30
0.60
0.35
20
30
35
0.30
Total rated
Air required (m
) for
3
consumption
burning 1 m
3
of gas
742 l/h
9.52
567 g/h
30.94

Advertisement

loading