Read this manual before operating the nebu-
lizer. Save this manual for future reference.
Federal Law (USA) restricts this device to sale by or on the
order of a physician. This device should not be used un-
less the operator has been instructed by a qualified health-
care professional.
LX2
®
JB0112-110-INS-LAB-RevB07

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for John Bunn Neb-u-Lite LX2

  • Page 1 Neb-u-Lite ® Nebulizer Compressor Item JB0112-110 User Manual Read this manual before operating the nebu- lizer. Save this manual for future reference. Federal Law (USA) restricts this device to sale by or on the order of a physician. This device should not be used un- less the operator has been instructed by a qualified health- care professional.
  • Page 2: Table Of Contents

    TROUBLEShOOTINg ....................11 SPECIFICATIONS .......................12 LIMITEd WARRANTy ....................13 GF, Graham-Field, John Bunn, and Neb-u-Lite are registered trademarks of GF Health Products, Inc. Packaging, warranties, products, and specifications are subject to change with- out notice. GF Health Products, Inc. is not responsible for typographical errors.
  • Page 3: Important Safeguards

    2. This product contains small parts that may present a choking hazard to small children, and the tubing may present a strangulation hazard. Always use close supervi- sion when this device is used by or near children or those who require close supervision. John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 4 14. Unplug the device before filling or cleaning the nebulizer. 15. This device is oil-free. do not lubricate. 16. do not remove the jet nebulizer while the device is operating. John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 5: Introduction

    SAvE ThESE INSTRUCTIONS INtRodUCtIoN This user manual contains important information and safety precautions for the John Bunn Neb-u-Lite LX2 Nebu- lizer Compressor. Before using your Nebulizer Compressor, please read and understand this entire user manual. Take special note of all safety precautions marked DANGER and WARNING.
  • Page 6: Product Description

    Please note nebulizer features and components, labeled in the illustration below. T adapter storage lid reservoir tube mouthpiece air outlet connector storage compartment filter cap ON/OFF switch nebulizer cup connector tubing Neb-u-Lite LX2 Nebulizer Compressor John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 7: Set-Up

    Proceed to step 9. install mask on cap T adapter 7. Insert mouthpiece into large end of mouthpiece T adapter. assemble mouthpiece and T adapter John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 8: Operation

    Caution: The Neb-u-Lite LX2 Nebulizer Compressor is designed for intermittent use only. Do not operate it continuously for more than 30 minutes for a single use without turning it off and allowing a cooling period of least 30 minutes.
  • Page 9: Safety Overload

    WARNINg: Unplug device before cleaning. do not sub- merge in water for cleaning. Wipe the compressor's outer case with a clean, damp cloth weekly to keep it dust-free. Do not use any powdered type cleaners or soap. John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 10: Cleaning The Nebulizer Cup

    Caution: Do not wash or clean the filter. Caution: Do not reuse the filter. Do not operate com- pressor without a filter. Compressor damage can result. Caution: The disposable nebulizer kit is for single pa- tient use only. John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 11: Storage

    Keep the device and accessories dry. Avoid exposure to direct sunlight. tRoUBleshootINg If your Neb-u-Lite LX2 Nebulizer Compressor fails to func- tion, consult the following Troubleshooting guide. If the problem persists, consult your Graham-Field dealer. Problem Cause and solution Device doesn’t...
  • Page 12: Specifications

    Temperature Operation: 50°F to 104°F (10°C to 40°C) Storage: 5°F to 122°F (-15°C to 50°C) Transport: 50°F to 104°F (-15°C to 70°C) Humidity Operation: 10% to 90% RH non-condensing Storage: 10% to 90% RH non-condensing Transport: 10% to 90% RH non-condensing John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 13: Limited Warranty

    GF Health Products, Inc. warrants the John Bunn JB0112-110 Nebulizer Compressor and its components to be free from defects in workmanship and materials as listed below:...
  • Page 14 TIES AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN, John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 15 GF Health Products, Inc. (“Graham-Field”) 2935 Northeast Parkway Atlanta, GA 30360 Tel 800-347-5678, Fax 800-726-0601 John Bunn Neb-u-Lite LX2 Nebulizer Compressor...
  • Page 16 USA, Corporate Headquarters: Graham-Field Health Products 2935 Northeast Parkway Atlanta, Georgia 30360 telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 www.grahamfield.com © 2007 GF Health Products, Inc. JB0112-110-INS-LAB-RevB07...
  • Page 17 Neb-u-Lite ® Compresor de Nebulizador Modelo JB0112-110 Manual de Usuario Lea antes de operar el nebulizador. guarde este manual para referencia en el futuro. La Ley Federal (USA) restringe este aparato para ventas por la orden de su médico. Este aparato no debe ser utilizado si el operador no ha sido adiestrado por profesional de cuido de salud cualificado.
  • Page 18 ALMACENAJE ......................11 dETECTANdO PROBLEMAS .....................11 ESPECIFICACIONES ......................12 gARANTíA .......................... 13 GF, Graham-Field y John Bunn, y Neb-u-Lite son marcas registradas de GF Health Products, Inc. Embalaje, garantías, productos y specificaciones son sujetos a cambiar sin aviso. GF Health Products, Inc. no es responsable por errores tipográficos.
  • Page 19: Directivas Importantes De Seguridad

    2. Este producto contiene piezas pequeñas que presenta riesgos de asfixia para niños, y la manga puede presentar riesgo de estrangulación. Supervisión cercana es necesa- ria cuando este producto esté utilizado cerca de niños o personas con impedimentos. John Bunn Neb-u-Lite LX2 Compresor de Nebulizador...
  • Page 20 Si no funciona de este modo, contacte un elec- tricista cualificado. No modifique el enchufe de ninguna manera. 14. desconecte el aparato antes de llenar el nebulizador. John Bunn Neb-u-Lite LX2 Compresor de Nebulizador...
  • Page 21: Introducción

    ESTAS INSTRUCCIONES INtRodUCCIóN Este manual del usuario contiene información importante y precauciones de seguridad para el John Bunn Neb-u-Lite LX2 Compresor de Nebulizador. Antes de usar su Com- presor de Nebulizador, favor de leer y entender el manual de usuario. Tome nota especial en todas las precauciones marcadas PELIGRO y ADVERTENCIA.
  • Page 22: Símbolos

    T tapa de almacenaje manga de reserva boquilla conector del enchufe de aire estuche de almacenaje tapa del filtro interruptor de ON/OFF taza del nebulizador conector manga Neb-u-Lite LX2 Compresor de Nebulizador John Bunn Neb-u-Lite LX2 Compresor de Nebulizador...
  • Page 23: Ensamblaje

    9. 7. Conecte la boquilla a la parte gran- adaptador T boquilla de del adaptador T. ensamblaje de adaptador T y boquilla John Bunn Neb-u-Lite LX2 Compresor de Nebulizador...
  • Page 24: Operación

    Precaución: El Neb-u-Lite LX2 Compresor de Nebuliza- dor está diseñado para uso solamente por periodos. No debe operarlo continuamente por más de 30 minutos en un uso sin apagarlo y dejar que se enfríe por lo me- nos 30 minutos.
  • Page 25: Seguridad En Caso De Sobrecarga

    AdvERTENCIA: desenchufe el aparato antes de limpiar. No sumerja bajo agua. Frote con un paño húmedo cada semana. No utilice deter- gentes en polvo o abrasivos que pueden dañar la carcasa. John Bunn Neb-u-Lite LX2 Compresor de Nebulizador...
  • Page 26: Limpieza De La Taza Del Nebulizador

    Precaución: No lave o limpie el filtro. Precaución: No reutilice el filtro. No opere sin filtro. El compresor puede ser dañado por este uso. Precaución: El kit del nebulizador desechable es para uso solamente de una persona. John Bunn Neb-u-Lite LX2 Compresor de Nebulizador...
  • Page 27: Almacenaje

    Mantenga el aparato y los accesorios secos. Evite sol direc- tamente. deteCtANdo PRoBleMAs Si su Neb-u-Lite LX2 Compresor de Nebulizador falla, con- sulte a la guía de Detectando Problemas debajo. Si el pro- blema continua, llame a su distribuidor de Graham-Field.
  • Page 28: Especificaciones

    Almacenaje: 5°F a 122°F (-15°C a 50°C) Transporte: 50°F a 104°F (-15°C a 70°C) Humedad Operación: 10% a 90% RH no condesado Almacenaje: 10% a 90% RH no condesado Transporte: 10% a 90% RH no condesado John Bunn Neb-u-Lite LX2 Compresor de Nebulizador...
  • Page 29: Garantía

    GF Health Products, Inc. garantiza el John Bunn JB0112-110 Com- presor Nebulizador y sus componentes a estar libre de defec- tos de materiales o mano de obra según listado debajo: Compresor: Cinco (5) Años...
  • Page 30 GF Health Products, Inc. LA GARANTíA PRECEDENTE ES EXCLUSIVA Y PRECEDE OTRAS GARANTíAS O GARANTíAS IMPLíCITAS, INCLUYENDO PERO NO LIMITADAS A GARANTíAS DE MERCADEABILIDAD O APTI- John Bunn Neb-u-Lite LX2 Compresor de Nebulizador...