John Bunn Neb-u-Tyke Neb-a-Doodle JB0112-070 User Manual

Nebulizer compressor

Advertisement

Quick Links

Nebulizer Compressor
Read this manual before operating the nebulizer.
Save this manual for future reference.
Federal Law (USA) restricts this device to sale by or
on the order of a physician. This device should not
be used unless the operator has been instructed by
a qualified healthcare professional.
Item JB0112-070
User Manual
Neb-u-Tyke
JB0112-070-INS-LAB-RevB14
®
®

Advertisement

Table of Contents
loading

Summary of Contents for John Bunn Neb-u-Tyke Neb-a-Doodle JB0112-070

  • Page 1 ® Neb-u-Tyke ® Nebulizer Compressor Item JB0112-070 User Manual Read this manual before operating the nebulizer. Save this manual for future reference. Federal Law (USA) restricts this device to sale by or on the order of a physician. This device should not be used unless the operator has been instructed by a qualified healthcare professional.
  • Page 2: Table Of Contents

    Graham-Field, John Bunn, Neb-u-Tyke and Neb-a-Doodle are registered trademarks of GF Health Products, Inc. © 2009, GF Health Products, Inc. JB0112-070-INS-LAB-RevB14...
  • Page 3: Introduction

    INTRODUCTION This user manual contains important information and safety precautions for the John Bunn Neb-u-Tyke Neb-a-Doodle Nebulizer Compressor. Before using your Nebulizer Compressor, please read and understand this entire user manual. Take special note of all safety precautions marked DANGER and WARNING. Save this user manual for future reference.
  • Page 4: Symbols Key

    Symbols Key Alternating current IPX0 Enclosed equipment without protection against ingress of water Attention (read the instructions) Class II (not applicable for UL1431) BF: This product is in accordance with the degree of protection against electric shock for type BF equipment. (not applicable for UL1431) Disposal of Electrical &...
  • Page 5: Important Safety Precautions

    IMPORTANT SAFETY PRECAUTIONS When using electrical products, especially when children are present, always follow basic safety precautions, including the following: DANGER: Indicates a potential hazard situation or unsafe practice that, if not avoided, will result in death or serious personal injury. WARNING: Indicates a potential hazard situation or unsafe practice that, if not avoided, could result in death or serious personal injury.
  • Page 6 WARNING: To reduce the risk of burns, electrocution, fire or personal injury: 1. Never leave this device unattended when plugged in. 2. This product contains small parts that may present a choking hazard to small children, and the tubing may present a strangulation hazard. Always use close supervision when this device is used by or near children or those who require close supervision.
  • Page 7 13. This device has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not modify the plug in any way. Do not attempt to defeat this safety feature. 14. Unplug the device before filling or cleaning the nebulizer. 15. This device is oil-free. Do not lubricate. 16. Do not remove the jet nebulizer while the device is operating. 17.
  • Page 8: Product Description

    PRODUCT DESCRIPTION Features and Components Please note nebulizer features and components, labeled in the illustration below. filter cap air outlet connector for tubing ON/OFF switch push button tubing reservoir tube mouthpiece nebulizer housing drawing board nebulizer cup T adapter adult mask pediatric mask shapes slide tab Neb-u-Tyke Neb-a-Doodle stylus Nebulizer Compressor Info: Neb-a-Doodle replacement parts are available JB0112-070-INS-LAB-RevB14...
  • Page 9: Setup

    SETUP Info: Before initial operation, clean the nebulizer cup assembly following the instructions given in MAINTENANCE/Cleaning the Nebulizer Cup. WARNING: Ensure that the nebulizer compressor is unplugged during setup. 1. Before each use, inspect the compressor and nebulizer cup assembly for damage or wear; replace as needed. 2.
  • Page 10 Info: The reservoir tube, shown in the illustration earlier in this manual, acts as a holding tank for the mist, reducing the amount lost during treatment. Its use is optional. If you wish to use the reservoir tube, install it now on the small end of the T adapter.
  • Page 11: Operation

    OPERATION arrow push button Info: The drawing board must be removed from the nebulizer housing before use. To remove the drawing board, push the button and slide the drawing board in the opposite direction from the cover arrow. Nebulizer Operation s NOTICE: The Neb-u-Tyke Neb-a-Doodle Nebulizer Compressor is designed for intermittent use only.
  • Page 12: Drawing Board Operation

    Drawing Board Operation arrow push button To remove the drawing board, push the button and slide the drawing board in the opposite direction from the cover arrow. To install the drawing board, insert the drawing board on the side with the housing arrow that matches the cover arrow, then push it all the way to secure it to the lock button.
  • Page 13: Safety Overload

    Safety Overload s NOTICE: Do not exceed 30 minutes of continuous operation. 1. The motor of this device has a built-in thermal overload protector. Should the motor overheat, the protector will automatically shut off the motor. Should this occur, move the ON/OFF switch to the OFF position and allow the motor to cool down for approximately 30 minutes before turning it on again.
  • Page 14: Maintenance

    MAINTENANCE Cleaning the Compressor’s Outer Case WARNING: Electrical shock hazard. Do not remove the outer case of the device. All disassembly and maintenance of the device must be performed by a qualified service technician. Refer service to qualified service personnel. WARNING: This device does not require oil. Do not attempt to lubricate any internal parts.
  • Page 15: Replacing The Filter

    Replacing the Filter s NOTICE: Change the filter once every 30 days or when the filter changes color. Additional filters can be purchased from Graham-Field authorized distributor. 1. Ensure that ON/OFF switch is in the OFF position. Open the filter cap located next to the ON/OFF switch. 2. Remove the dirty filter with a small, pointed object. Discard the filter. 3.
  • Page 16: Troubleshooting

    TROUBLESHOOTING If your Neb-u-Tyke Neb-a-Doodle Nebulizer Compressor fails to function, consult the following Troubleshooting guide. If the problem persists, consult your Graham-Field authorized distributor. Problem Cause and Solution Device doesn’t Check if plug is properly fit into a grounded electrical outlet. operate When device has been run continuously for more than 30 minutes just before using, auto-shut-down may have been activated by the...
  • Page 17: Specifications

    SPECIFICATIONS Specification Description Max pressure (compressor) 32.5 PSI Max flow rate Approximately 12 LPM Nebulization rate .33 ml/min Particle dimension .5 - 5 microns Capacity 5 ml Filter Sponge Dimensions (LxWxH) 10" × 6.5" × 4.2" (255 mm x 166 mm x 108 mm) Weight 4 lb (1860 g) Electrical requirement...
  • Page 18: Limited Warranty

    LIMITED WARRANTY SCOPE OF WARRANTY GF Health Products, Inc. (“GF”) warrants to the original purchaser only that it will replace or repair components, at GF’s sole discretion, that are defective in material or workmanship under normal use and service. All warranties are conditioned upon the proper use of the products strictly in accordance with good commercial practice and applicable GF instructions and manuals, including proper use and maintenance.
  • Page 19 ENTIRE WARRANTY, EXCLUSIVE REMEDY AND CONSEQUENTIAL DAMAGES DISCLAIMER THIS WARRANTY IS GF’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. GF MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Page 20 Manufactured for: GF Health Products, Inc. Made in China...