Shortening Of "Maintenance Cycle" And "Replacement Cycle" Needs To Be Considered In Following Situations; Important Information Regarding The Refrigerant Used - Daikin REYAQ10P7Y1B Operation Manual

Vrviii system air conditioner
Table of Contents

Advertisement

NOTICE
1.
Table 1 indicates main components.
Refer to your maintenance and inspection contract for
more details.
2.
Table 1
indicates
maintenance cycles. However, in order to keep the
unit operational as long as possible, maintenance
work may be required sooner.
Recommended intervals can be used for appropriate
maintenance
maintenance and inspection fees. Depending on the
content of the maintenance and inspection contract,
inspection and maintenance cycles may in reality be
shorter than listed.
11.2. Shortening of "maintenance cycle" and
"replacement cycle" needs to be considered in
following situations
The unit is used in locations where:
1.
heat and humidity fluctuate out of the ordinary
2.
power fluctuation is high (voltage, frequency, wave distortion,
etc.)
(The unit cannot be used if power fluctuation is outside the
allowable range.)
3.
bumps and vibrations are frequent
4.
dust, salt, harmful gas or oil mist such as sulfurous acid and
hydrogen sulfide may be present in the air
5.
the machine is started and stopped frequently or operation time
is long (sites with 24 hour air-conditioning).
Recommended replacement cycle of wear parts
Table 2: "Replacement Cycle" list
Component
Air filter
High efficiency filter (Optional)
Fuse
Crankcase heater
NOTICE
1.
Table 2 indicates main components.
Refer to your maintenance and inspection contract for
more details.
2.
Table 2
indicates
replacement cycles. However, in order to keep the
unit operational as long as possible, maintenance
work may be required sooner.
Recommended intervals can be used for appropriate
maintenance
maintenance and inspection fees.
Contact your dealer for details.
INFORMATION
Damage due to taking apart or cleaning interiors of units
by anyone other than our authorised dealers may not be
included in the warranty.
Moving and discarding the unit
■ Contact your dealer for removing and reinstalling the total
unit. Moving units requires technical expertise.
■ This unit uses hydrofluorocarbon.
Contact your dealer when discarding this unit. It is required
by law to collect, transport and discard the refrigerant in
accordance with the "hydrofluorocarbon collection and
destruction" regulations.
HXHD125A7V1B
VRVIII system air conditioner
4PW62583-1 – 11.2010
recommended
intervals
design
in
terms
of
budgetting
Maintenance cycle
(replacements and/
Inspection cycle
or repairs)
5 years
1 year
1 year
10 years
8 years
recommended
intervals
design
in
terms
of
budgetting
12. I
MPORTANT INFORMATION REGARDING THE
REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.
of
Refrigerant type:
R410A
(1)
GWP
value:
1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.
of
Operation manual
10