Manuel d’utilisation Français Conditionneur d’air VRV System Manual de operación Español Sistema de acondicionador de aire VRV Manuale d’uso Italiano Condizionatore d’aria a sistema VRV REYQ8PY1B REYQ10PY1B Εγχειρßδιο λειτουργßαò REYQ12PY1B ΕλληνικÜ Κλιìατιστικü ìε σýστηìα VRV REYQ14PY1B REYQ16PY1B Gebruiksaanwijzing Nederlands Airconditioner met VRV...
Page 2
Muito obrigado por ter adquirido este aparelho de ar condicionado era en cas de panne. Après avoir lu le manuel, rangez-le en vue Daikin. Antes de utilizar o aparelho, leia atentamente o presente manual d’une utilisation ultérieure. de funcionamento. Nele obterá informações sobre o modo de utilizar Pour plus de détails concernant l’unité...
REYQ8PY1B REYQ10PY1B Operation manual REYQ12PY1B VRVIII System air conditioner REYQ14PY1B REYQ16PY1B CONTENTS • Flammable if refrigerant leaks. The refrigerant used in the air conditioner is safe 1. SAFETY CAUTIONS........1 and should not normally leak, but if it does leak into a room, it will emit a noxious gas if it comes in 2.
Page 6
• Do not locate combustion appliances in places • Consult with the dealer for cleaning the interior exposed to the air that blows from the air con- of the indoor units. ditioner. Incorrect cleaning may damage the plastic parts The airflow may cause incomplete combustion of and cause failures, such as water leakage, and an the combustion appliances.
• Do not use the air conditioner in the following 2. SPECIFICATIONS places. Model name REYQ8PY1B REYQ10PY1B REYQ12PY1B a. Places with a mist of mineral oil, such as cutting Power supply oil. Phase b. Locations such as coastal areas where there is...
Before initiating operation, 9. Display “ ” (inspection/test operation) contact your Daikin dealer for the operation that cor- TEST When the inspection/test operation button is responds to your system type and mark. pressed, the display shows the mode in which If your installation has a customized control system, the system actually is.
6. OPERATION PROCEDURE 23. Fan only/air conditioning selector switch Set the switch to “ ” for fan only operation or to • Operation procedure varies according to the com- “ ” for heating or cooling operation. bination of outdoor unit and remote controller. 24.
Page 10
ADJUSTMENT (Refer to figure 4) Defrost operation For adjustment the desired temperature, fan • In heating operation, freezing of the outdoor speed and air flow direction (only for the unit heat exchanger increases. Heating remote controller BRC1A51: FXC, FXF, FXH, capability decreases and the system goes FXK, FXA), follow the procedure shown below.
Page 11
FXC, FXF, FXH, FXK, FXA). Refer to the • The movable limit of the flap is changeable. chapter “6-3 ADJUSTING THE AIR FLOW Contact your Daikin dealer for details. (Only DIRECTION” for details. for Double-flow, Multi-flow, Corner, Ceiling- Press the on/off button once again.
Page 12
Press the timer mode start/stop button several 5. COOL/HEAT Selector times and select the mode on the display. 6. The COOL/HEAT Selector is connected to The display flashes. BS unit. The COOL/HEAT Selector can select opera- • For setting the timer stop “ ”...
NOTE We recommend starting the operation in advance using timer operation. • Contact your Daikin dealer in case of chang- ing the combination or setting of group con- trol and two remote controller control 8. SEASONAL MAINTENANCE systems.
Operation automatically restarts when the noise room becomes uneven. It is necessary to clean goes away. the interior of the indoor unit. Ask your Daikin dealer for details on cleaning the unit. This opera- tion requires a qualified service person.
Page 15
• Immediately after the cooling operation stops 9-10 THE UNITS CAN GIVE OFF ODOURS and if the room temperature and humidity are • During operation. low. The unit can absorb the smell of rooms, furniture, This is because warm refrigerant gas flows back cigarettes, etc., and then emit it again.
4. Malfunction code • Check if the heat source of the room is excessive Measure: Notify your Daikin dealer and report the during cooling operation. malfunction code. • Check if direct sunlight enters the room during If the system does not properly operate except cooling operation.
Page 17
• Do not remove or reinstall the unit by yourself. • Table 1 “Inspection Cycle” and “Maintenance Incorrect installation may cause electrical shock or Cycle” Lists fire. Maintenance Cycle Inspection Contact your dealer. Name of Main Part [replacements and/or Cycle repairs] Compressor 20,000 hours...
Page 18
Note 2 This maintenance cycle indicates recommended lengths of time until the need arises for maintenance work, in order to ensure the product is operational as long as possible. Use for appropriate maintenance design (budgeting maintenance and inspection fees, etc.). Contact your dealer for details.