LASER SAFETY LABEL REPRODUCTIONS

There is only one laser aperture on this
product. This label indicates the laser beam
output aperture.
Caution – Class 3B LASER RADIATION, WHEN OPEN,
AVOID EXPOSURE TO BEAM.

LASER EMISSION DATA*

Laser Classification
Red Laser Medium
Green Laser Medium
Blue Laser Medium
Beam Diameter
Divergence (each beam)
Divergence (total light)
* As measured under IEC measurement conditions for classification.

LASER COMPLIANCE STATEMENT

This laser product complies with EN/IEC 60825-1 Ed 2, 2007-03.
Safety Notes
4
Class 3B
LD GaAlAs 650 nm, typical
DPSS Nd:YVO4, 532 nm
LD GeAs 450 nm, typical
<5 mm at aperture
Pulse Data
All pulses <4 Hz (>0.25 sec)
<2 mrad
<30 degrees
Cooling
Fan Cooling
Scanning
ILDA Standard: 15 Kpps
This device was shipped in perfect condition. In order to maintain this condition and to
ensure safe operation, follow the safety instructions and warning notes written in this
manual. Every person involved with installation and maintenance of this device has to:
Be qualified
Follow the instructions in this manual
CAUTION! Be careful when operating. DO NOT touch the housing or wires when the
product is on to avoid a dangerous electric shock!
Important! CHAUVET® will not accept liability for any resulting damage caused by the
non-observance of this manual or any unauthorized modification to the device. Any
modifications to the product will void any warranty.
This product is not intended for permanent installation.
DO NOT mount this product within 50 cm of surrounding walls or large obstacles to
allow for ventilation.
Never let the power-cord come into contact with other cables! Handle the power-cord
and all connections with the mains with particular caution!
Make sure that the available voltage is not higher than stated on the rear panel.
Make sure that the power-switch is set to off-position before you connect the device
to the mains. Make sure the power plug is accessible after mounting the device.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check
the device and the power-cord from time to time.
Scorpion Scan 300 RGB EU User Manual (Rev. 1 ML)