ATX SignalOn Series User Manual

Rf switch module

Advertisement

SignalOn
RF Switch Module
User Manual
Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions.
Specifications subject to change without notice.
Series
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SignalOn Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATX SignalOn Series

  • Page 1 SignalOn Series ® RF Switch Module User Manual Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice.
  • Page 2 SignalOn Series is a registered trademark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or ® foreign patents. Other non-ATX product and company names in this manual are the property of their respective companies.
  • Page 3: Table Of Contents

    6.1. Input RF Level Calibration ......................... 6-3 6.2. RF Input Level Calculation ........................ 6-3 6.3. Protection Switching .......................... 6-4 6.4. Alarm Contact Closure ........................6-4 SERVICE & SUPPORT ..........................7-1 7.1. Contact ATX Networks ........................7-1 7.2. Warranty Information ......................... 7-1 7.3. Safety ..............................7-1...
  • Page 4 Index of Figures and Tables Figures Single RF Switch Module..................1-1 Dual RF Switch Module ..................1-1 General Application Amplifier Redundancy............3-1 General Application Path Redundancy ..............3-1 RF Switch Module Installation 2RU Chassis ............5-1 RF Switch Module Installation 5RU Chassis ............5-2 Single RF Switch Module..................6-2 Dual RF Switch Module ..................6-2 Tables Physical and Environmental Specifications ............4-1...
  • Page 5: Introduction

    PREFACE Introduction The SignalOn Series RF Switch Module is designed to be installed in the 8- or 20-position SignalOn Series chassis. Each RF switch module occupies two positions in the chassis. The mechanical dimensions, cable management, and aesthetics of the RF Switch Module are compatible with the SignalOn product line. The system is designed to accommodate superior cable management and ease of use.
  • Page 6 PREFACE This page left intentionally blank. SignalOn ® Series – RF Switch Module User Manual...
  • Page 7: General

    CHAPTER 1: GENERAL GENERAL General The SignalOn system is a modular system that permits high isolation combining, splitting, switching, and amplification of headend signals in a CATV system. The system is designed to accommodate strong cable management, EMI shielding, and ease of use.
  • Page 8 CHAPTER 1: GENERAL This page left intentionally blank. SignalOn ® Series – RF Switch Module User Manual...
  • Page 9: Product Description

    CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTION Product Description Primary function of the module is to monitor the RF signal gain on the operating primary “A” input, and switch to the backup “B” input if the gain of the primary path rises, or falls below the calibrated RF input level of the unit. If the “A” input side goes above, or falls below the threshold of the unit, the RFSM quickly switches the input from the failed input to the secondary input.
  • Page 10 CHAPTER 2: PRODUCT DESCRIPTION This page left intentionally blank. SignalOn ® Series – RF Switch Module User Manual...
  • Page 11: Applications

    CHAPTER 3: APPLICATIONS APPLICATIONS Applications Typical applications of this switch are to protect two optical to RF receivers, or redundant amplifiers. In this setup, the RFSM can independently protect one or two pairs of receivers, or amplifiers. Once the RFSM detects a signal level rising above, or falling below the preset threshold level, it switches from A to B or B to A for that RFSM.
  • Page 12 CHAPTER 3: APPLICATIONS This page left intentionally blank. SignalOn ® Series – RF Switch Module User Manual...
  • Page 13: Specifications

    CHAPTER 4: SPECIFICATIONS SPECIFICATIONS Specifications Specifications are noted in Table 1, and Table 2. PARAMETER SPECIFICATIONS REMARKS Physical Dimensions (W × D × H) 1.7 × 5.9 × 8.5 inches (4.3 ×14.9 × 21.6 cm) Weight Single 1.54 pounds (0.7 kg) Dual 1.86 pounds (0.8 kg) Environmental...
  • Page 14 CHAPTER 4: SPECIFICATIONS This page left intentionally blank. SignalOn ® Series – RF Switch Module User Manual...
  • Page 15: Installation

    Series chassis. 1. Make sure the ATX logo (or any other front panel lettering) is readable. Align the power connector at the top of the module with the power connector in the chassis. Slide the plugin module into its designated location in the chassis.
  • Page 16: Rf Switch Module Installation 5Ru Chassis

    CHAPTER 5: INSTALLATION DUAL RF SWITCH MODULE Figure #6: RF Switch Module Installation 5RU Chassis SignalOn ® Series – RF Switch Module User Manual...
  • Page 17: System Operation

    CHAPTER 6: SYSTEM OPERATION SYSTEM OPERATION System Operation There are four LEDs and two bar graph indicators, one toggle switch, and a SET button on the front panel of the single switch module. The dual switch module has two sets of indicators and controls on the front panel. Refer to Table 3 for a description of the rear connectors and DIP switches.
  • Page 18: Single Rf Switch Module

    CHAPTER 6: SYSTEM OPERATION FRONT VIEW REAR VIEW Figure #7: Single RF Switch Module FRONT VIEW REAR VIEW Figure #8: Dual RF Switch Module SignalOn ® Series – RF Switch Module User Manual...
  • Page 19: Input Rf Level Calibration

    CHAPTER 6: SYSTEM OPERATION 6.1. Input RF Level Calibration Calibration is performed using the SET button. The RFSM compares each RF input level to a user-selected ±3 dB or ±6 dB switching threshold, and to minimum/maximum input limits. To pass calibration, when B-Relative-To-A Mode is selected, the power level of B must be within the threshold window of A.
  • Page 20: Protection Switching

    CHAPTER 6: SYSTEM OPERATION 6.3. Protection Switching Upon detecting a path failure, the RFSM switches to the alternate path within 10ms. Table 6 indicates the switching logic of the RFSM based on input conditions: RFSM CONFIGURATION RELAY ACTION User has Manually Selected Path-A Never Switched;...
  • Page 21: Service & Support

    Please contact ATX Technical Support for assistance with any ATX products. Please contact ATX Customer Service to obtain a valid RMA number for any ATX products that require service and are in or out-of-warranty before returning a failed module to the factory.
  • Page 22 1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Tel +1 (905) 428-6068 Toll Free +1 (800) 565-7488 Fax +1 (905) 427-1964 Toll Free Fax +1 (866) 427-1964 www.atxnetworks.com support@atxnetworks.com Printed in Canada Rev. 08/12 (ANW0846)

Table of Contents