Compliant
Return Path Amplifi er
INSTALLATION & OPERATION MANUAL
www.atxnetworks.com
www.atxnetworks.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SignalOn Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ATX SignalOn Series

  • Page 1 SignalOn Series ® D3.1/CCAP ™ 1.2 GHz Compliant Return Path Amplifi er INSTALLATION & OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com...
  • Page 2 ® service mark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-ATX product and company names in this manual are the property of their respective companies.
  • Page 3: Table Of Contents

    3.2. Reverse Path ............................. 3-1 MAINTENANCE ............................4-1 4.1. Preventative Maintenance ......................... 4-1 SERVICE & SUPPORT ..........................5-1 5.1. Contact ATX Networks ........................5-1 5.2. Warranty Information ......................... 5-1 5.3. Safety ..............................5-1 SignalOn Series – Return Path Amplifier – Installation & Operation Manual...
  • Page 4 Index of Figures and Tables Figures SignalOn Return Path Amplifier ................2-1 ® Return Path Amplifier Schematic Diagram ............2-1 Reverse Path Example ..................3-1 Tables Specifications......................2-2 SignalOn Series – Return Path Amplifier – Installation & Operation Manual ®...
  • Page 5: About This Manual

    PREFACE About This Manual The SignalOn Return Path Amplifi er covered in this user manual is part of the SignalOn family of plug-in modules. The Return Path Amplifi er provides gain amplifi cation with low distortion and low noise for a broadband communications system return path (5 MHz to 200 MHz).
  • Page 6 PREFACE MIL-STD-202 Military Standard for Thermal Shock Requirements. FCC Part 15 and 76 Federal Communication Commission CFR 47 Code of Federal Regulations SignalOn Series – Return Path Amplifier – Installation & Operation Manual ®...
  • Page 7: General

    CHAPTER 1: GENERAL GENERAL General This user manual describes the features, functions, and installation procedures for the SignalOn Return Path Amplifier, chassis, power supply, and adapter kit. 1.1. Return Path Amplifier The Return Path Amplifier provides gain amplification with low distortion and low noise for a broadband communications system return path (5 MHz to 200 MHz).
  • Page 8 CHAPTER 1: GENERAL This page left intentionally blank. SignalOn Series – Return Path Amplifi er – Installation & Operation Manual ®...
  • Page 9: Product Description

    CHAPTER 2: PRODUCT DESCRIPTION PRODUCT DESCRIPTION Product Description This section provides physical, functional, and technical descriptions of the SignalOn Return Path Amplifier, four-position horizontal chassis, 100–240 VAC power supply, and –48 VDC power supply. 2.1. Physical Description 2.1.1. Return Path Amplifier The SignalOn Return Path Amplifier is constructed of aluminum sheet metal with nickel plating. The amplifier has two sets of BNC-type or F-type RF connectors (depending on model ordered): Monitor Port Before Amp (MON IN) and Monitor Port After Amp (MON OUT) located in the front of the module, and RF IN and RF OUT, located at the rear.
  • Page 10: Technical Description

    CHAPTER 2: PRODUCT DESCRIPTION 2.3. Technical Description Forward Path Amplifier 20 dB FORWARD AMPLIFIER 30 dB FORWARD AMPLIFIER 30 dB FORWARD AMPLIFIER BANDWIDTH 50-1002 MHz 50-1002 MHz 50-1218 MHz MINIMUM RF INPUT +20 dBmV per Channel +10 dBmV per Channel +10 dBmV per Channel MINIMUM FULL GAIN 20 dB...
  • Page 11: Operating Instructions

    CHAPTER 3: OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Operating Instructions There are no specific operating instructions for the SignalOn Return Path Amplifier. Once the amplifier is installed, it will perform its designated RF signal management function without further attention. As detailed below, the amplifier includes convenient Monitor (MON) ports where test equipment can be connected to the system as necessary.
  • Page 12 CHAPTER 3: OPERATING INSTRUCTIONS This page left intentionally blank. SignalOn Series – Return Path Amplifi er – Installation & Operation Manual ®...
  • Page 13: Maintenance

    4.1. Preventative Maintenance No user maintenance is required on this unit. NOTE: There are no customer serviceable parts in the SignalOn Return Path Amplifi er. Return all failed units to ATX Networks for service or repair. SignalOn Series – Return Path Amplifi er – Installation & Operation Manual...
  • Page 14 CHAPTER 4: MAINTENANCE This page left intentionally blank. SignalOn Series – Return Path Amplifi er – Installation & Operation Manual ®...
  • Page 15: Service & Support

    Please contact ATX Technical Support for assistance with any ATX products. Please contact ATX Customer Service to obtain a valid RMA number for any ATX products that require service and are in or out-of-warranty before returning a failed module to the factory.