Approved Venting Configurations with a Horizontal Termination
•
If using a Snorkel Termination (14" or 36") add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).
•
The termination must fall within the shaded area shown in the chart. Use restrictor position #1.
Natural Gas (NG)
Installations
10' (max)
5 feet
0 feet
Propane (LP)
Installations
11' (max)
5 feet
0 feet
Travis Industries
(for qualified installers only)
Use Restrictor Position # 1
(all shaded areas)
NOTE:
A minimum 2 foot rise is required
directly off of the stove.
Use Restrictor Position # 1
(all shaded areas)
NOTE:
A minimum 3 foot rise is required
directly off of the stove.
100-01135
NOTE:
Horizontal sections
require a 1/4" rise every
10' (max)
12" of travel.
5 feet
0 feet
NOTE:
Horizontal sections
require a 1/4" rise every
11' (max)
12" of travel.
5 feet
0 feet