Table 13. Power Profiles - Dell PowerEdge R210 II Technical Manual

Ultra-dense 1-socket 1u rack server
Hide thumbs Also See for PowerEdge R210 II:
Table of Contents

Advertisement

Dell
Table 13 shows the power profile options for the R210 II.
Maximum Performance
OS Control
Custom
PowerEdge R210 II Technical Guide
Table 13.
Power Profiles
DBPM Disabled (BIOS sets P-State to max)
Memory frequency = Maximum Performance
Fan algorithm = Maximum Performance
Enable OS DBPM Control (BIOS exposes all possible P states to
OS)
Memory frequency = Maximum Performance
Fan algorithm = Minimum Power
CPU Power and Performance Management:
Maximum Performance | Minimum Power | OS DBPM | System
DBPM
Memory Power and Performance Management:
Maximum Performance |1333Mhz |1067Mhz |800Mhz|
Minimum Power
Fan Algorithm
Maximum Performance | Minimum Power