Kohler Command PRO ECH630 Service Manual page 71

Horizontal crankshaft
Hide thumbs Also See for Command PRO ECH630:

Advertisement

OBD2
P-Code Ap-
Blink
plicable to:
Code
"32 Pin" (MSE
1.1) ECU/Sys-
tem Only
31
P0132
32
P0134
33
P0175
33
P0020
34
P0171
34
P0172
42
P0117
42
P0118
43
N/A
44
N/A
51
P1260
51
P0261
51
P0262
52
P1263
52
P0264
52
P0265
55
P1651
55
P1652
55
P1653
24 690 01 Rev. D
Connection or Failure Description
O
Sensor Circuit: Shorted to Battery
2
O
Sensor Circuit: No Activity De-
2
tected
System too Rich
O
Sensor Control at Upper Limit
2
Maximum Adaption Limit Reached
Minimum Adaption Limit Reached
Temperature Sensor Circuit: Shorted
to Ground
Temperature Sensor Circuit: Open
Circuit or Short to Battery
Failure Completing Autolearn - TPS
Offset below minimum allowable limit
Failure Completing Autolearn - TPS
offset above maximum allowable
limit
Injector 1-Open Circuit
Injector 1-Short Circuit to Ground
Injector 1-Short Circuit to Battery
Injector 2 - Open Circuit
Injector 2-Short Circuit to Ground
Injector 2-Short Circuit to Batt
Diagnostic Lamp - Open Circu
Diagnostic Lamp - Short Circuit to
Ground
Diagnostic Lamp-Short Circuit to
Battery
KohlerEngines.com
EFI SYSTEM-BOSCH
"35 Pin"
"24 Pin"
(MA 1.7)
(MSE 1.0)
Metal-
Plastic-
Cased
Cased
ECU/
ECU/Sys-
System
tem
Y
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
"32 Pin"
(MSE
1.1)
Note
Plastic-
Cased
ECU/
System
Y
3
N
8
7,8
Y
8
Y
8
Y
8
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y