12
Check that the front insulation slab is properly attached to the inner front
panel and refit panel (insulation innermost) to the heater by locating its
bottom edge behind the front lip of the chassis, and inserting retaining
screws along the top and both sides. With the bricks pushed well back,
as mentioned earlier, and the insulation properly aligned, there should be no bulging of this
panel and no undue force necessary to fix it.
Refit the lower front panel by aligning the four side screws before refitting the front face
screws. With the lower front panel in place, the outer panel assembly can be hooked
over the rear panel top flange and the screws top and bottom replaced and tightened.
Take care not to trap wires or the thermostat capillary between the panel flanges. Ensure all washers are replaced in their
original positions.
Refit the control knobs under the lift - up flap, taking care to align the flat on each spindle.
PLEASE ENSURE THAT ALL POLYSTYRENE AND CARDBOARD PACKING PIECES HAVE BEEN REMOVED.
ENSURE WALL BRACKET SCREWS ARE TIGHTENED FULLY.
WARNING. When a new heater is run up to temperature, the materials will produce a slight smell for the first few days,
these are normally harmless in a well ventilated room. It is best to make these first overnight charges with the 'Input'
control knob at 'Maximum'. Caged birds, young children and people with chest ailments are best kept out of the room
for this first period.
AUTOMATIC CHARGING DEVICE (AUTO-SET Fitted only on 'ACW' model) The Auto-Set
Control rations the overnight charge each night by sensing the room temperature.
The knob is marked with the numbers 1 to 6, turning the knob to a lower number will reduce the charge consequently,
the level of room warmth the next day.
Once set, the knob should need no further adjustment and the Auto-Set will maintain automatically the room warmth
each day by varying the charge according to the weather.
1. Set the room temperature (output) control knob to setting 4.
2. Turn the Auto-Set Knob clockwise as far as it will go.
3. Leave the heater to run in this condition for two nights in order to quickly disperse the 'new' smell which although
slight, is better removed once and for all.
4. Instruct the user to set the Auto-Set down to his chosen setting on the third day.
Instructions on this are given in the Users Guide which we ask you to ensure is left with the user.
MANUALLY ADJUSTED HEATER (without Auto-Set Control)
On this the user sets the overnight charge on the numbered knob marked 'Input'.
Setting up procedure;
1. Turn the 'lnput' knob to maximum setting (6)
2. Set the 'Output' knob to setting No. 4.
3. Leave the heater to run in this condition for two nights in order to quickly disperse the new smell.
4. Instruct the user to set the 'Input' to his chosen setting on the third day. Instructions on this are given in the Users
Guide which we ask you to ensure is left with the user.
Part No. 88013
Iss. No. 6

SETTING THE CONTROLS

The controls are located under the lockable flap at the right
hand corner of the top panel. To adjust the controls on the
heater use a coin and engage it in the slot provided on the
top surface of the knob.