Check that the front insulation slab is properly attached to the inner
front panel and refit panel (insulation innermost) to the heater by
locating its bottom edge behind the front lip of the chassis, and
inserting retaining screws along the top and both sides. With the bricks
pushed well back, as mentioned earlier, and the insulation properly aligned, there should
be no bulging of this panel and no undue force necessary to fix it.
Refit the front / top assembly by hooking the rear edge of the top panel over the rear edge of the casing, then swing the
front panel carefully down against the casing. Replace the screws along the rear of the top and the base of the front
panel which had been removed in Step 5. ENSURE WALL BRACKET SCREWS ARE TIGHTENED FULLY.
WARNING. When a new heater is run up to temperature, the materials will produce a slight smell for the first few days,
these are normally harmless in a well ventilated room. It is best to make these first overnight charges with the 'Charge
Controller/Auto-Set' knob at 'Maximum'. Caged birds, young children and people with chest ailments are best kept
out of the room for this first period.
WET BRICKS: If accidentally, the bricks have become wet due to their having been left out-of-doors, some moisture may
be driven off during the first overnight charging and this may drip on to the floor. If there is any doubt on this score,
advise the customer to lay newspaper beneath the heater to protect carpets etc. REFIT THE CONTROL KNOBS: PLEASE
OBSERVE THE FLAT ON THE 'D' SHAPED SPINDLE ALIGNS WITH THE FLAT ON THE KNOB BOSS.

SETTING THE CONTROLS

AUTOMATIC CHARGING DEVICE (AUTO-SET Fitted only on Sensor Plus) The Auto-Set Control rations the
overnight charge each night by sensing the room temperature.
The knob is marked with the numbers 1 to 6, turning the knob to a lower number will reduce the charge consequently,
the level of room warmth the next day.
Once set, the knob should need no further adjustment and the Auto-Set will maintain automatically the room warmth
each day by varying the charge according to the weather.
1. Set the room temperature (output) control knob to setting 4.
2. Turn the Auto-Set Knob clockwise as far as it will go.
3. Leave the heater to run in this condition for two nights in order to quickly disperse the 'new' smell which although
slight, is better removed once and for all.
4. Instruct the user to set the Auto-Set down to his chosen setting on the third day.
Instructions on this are given in the Users Guide which we ask you to ensure is left with the user.
MANUALLY ADJUSTED HEATER (without Auto-Set Control)
On this the user sets the overnight charge on the numbered knob marked 'Input'.
Setting up procedure;
1. Turn the 'lnput' knob to maximum setting (6)
2. Set the 'Output' knob to setting No. 4.
3. Leave the heater to run in this condition for two nights in order to quickly disperse the new smell.
4. Instruct the user to set the 'Input' to his chosen setting on the third day. Instructions on this are given in the Users
Guide which we ask you to ensure is left with the user.
Part No. 84299
Iss. No. 11 08/10
The controls are located under the lockable flap at
the right hand corner of the top panel. To adjust the
controls on the heater use a coin and engage it in the
slot provided on the top surface of the knob.