6.9
Machine external specification
Dimensions
Mass
Lens mount
Flange back
Camera body grounding
insulation status
6.10 Operation Ambient conditions
Operation assurance
Storage assurance
EMC condition
Notes on Heat Radiation:
The temperature of camera housing must be kept less than 50
Please provide sufficient heat radiation depending on your installation.
Notes on Conformity of the EMC:
The adaptability of the safety standard of this camera is assured in the condition of combination with
the following parts:
<<PoE operation>>
- PoE Switch
- LAN Cable
<<DC operation>>
- DC Cable
- LAN Cable
Please confirm the EMC adaptability when it combines with parts other than them.
Copyright © 2013 TOSHIBA TELI CORPORATION, All rights reserved.
29 mm(W) x 29 mm (H) x 40 mm (D) (Not including protrusion)
Non-conductive between circuit GND and camera body
Temperature: 0°C to +40 °C, Camera housing temperature: less than 50 °C
Humidity: 10% to 90% (no condensation)
Temperature: -20°C to +60 °C
Humidity: 90% or less (no condensation)
EMI (Electro-Magnetic interference) : EN61000-6-4
EMS (Electro-Magnetic susceptibility) : EN61000-6-2
GS108P-100AJS
C5e(S-HFR)(K)-*
CPCBG-03
C5e(S-HFR)(K)-*
Approximately 53g
C-mount
17.526 mm
FCC Part 15 Subpart B Class A
°C
.
(NETGEAR Inc.)
(Oki Electric Cable Co., Ltd.)
(Oki Electric Cable Co., Ltd.)
17
http://www.toshiba-teli.co.jp/index.htm