Toshiba teli BG030 Specification page 16

Bg b/w series
Hide thumbs Also See for BG030:
Table of Contents

Advertisement

6.2
Internal sync signal specification
Model
Fundamental clock
frequency
6.3
Electronic shutter specification
Exposure time
MANUAL
AE effective range
AE effective area
AE Exposure value
6.4
Random Trigger Shutter specification
Trigger Mode
External trigger
Input level
Input Current
Polarity
Pulse width
Input circuit
Software trigger
Exposure time
Timed mode
TriggerWidth mode
Trigger Delay
Anti-Chattering
sampling period
Copyright © 2013 TOSHIBA TELI CORPORATION, All rights reserved.
BG030
BG031
50.000 MHz
50.000 MHz
± 100ppm
± 100ppm
MANUAL, AE (factory setting: MANUAL)
10µs to 16s
10µs to 16s
10µs to 16s
10µs to 16s
Full (Full pixel) / Medium (Central: 80% x 80%) / Small (Central: 40% x 40%)
External trigger, Software trigger (factory setting: External trigger)
Low: 0 to 0.5V, High: 3.3 to 24.0V
High active / Low active (factory setting: Low active)
External Trigger Signal Input Circuit
LINE0
(2pin)
(5pin)
I/O_GND
* Depending on cable length, cable kinds and input current of trigger input
line, Random Trigger Shutter operation may not satisfy timing specification
or camera may not receive EXT_TRIG signal.
GigE Vision Command (GVCP) control
Timed mode, TriggerWidth mode (factory setting: Timed)
The exposure time depends on the MANUAL Exposure time setting
The exposure time depends on External trigger width
0 to 4095µs (factory setting: 0µs)
2 to 1,000µs (factory setting: 2µs)
14
BG080
45.000 MHz
± 100ppm
30µs to 16s
30µs to 16s
±2EV
Input via I/O connector (Line0)
5 to 15mA
200µs (minimum)
Photo coupler input
TLP291
http://www.toshiba-teli.co.jp/index.htm
BG130
BG202
50.000 MHz
48.000 MHz
± 100ppm
± 100ppm
30µs to 16s
30µs to 16s
30µs to 16s
30µs to 16s
Vcc
TRIG_IN
GND
D4211883D