LSC DP-1210 User Manual

12 ch digital module dimmer

Advertisement

Quick Links

English
USER'S MANUAL
DMX
MENU
UP
DOWN
ESC
Please read before use

Advertisement

Table of Contents
loading

Summary of Contents for LSC DP-1210

  • Page 1 English USER'S MANUAL MENU DOWN Please read before use...
  • Page 3: Table Of Contents

    Contents Features 1 General Instructions 2 1. Overview 3 1.1 Front View 3 1.2 Rear View 5 2. Operation Guide 7 2.1 Display and standby mode 7 2.2 Set-up Menus 8 2.2.1 DMX fail 8 2.2.2 Phase Correction 9 2.2.3 DMX Address 10 2.2.4 Preheat 11 2.2.5 Curve 13 2.2.6 Preset 14...
  • Page 4: Features

    Features Thank you for your purchase. This product features include: 12 DMX channel Individual DMX address / Block address Individual channel dimmer / Master dimmer Each channel can be programmed with the DMX address, and the preheat of the lamps(0-50%). Any of 12 chase programs can be recalled as required, chase speed is adjustable Chase programs 1-12, DMX Hold, Analogue can be selectable...
  • Page 5: General Instructions

    General Instructions Please read through this operating instructions before installing or using your new product. After you have finished reading the instructions, put them away in a safe place for future reference. WARNING! This product must be earthed. To prevent fire or shock hazard, do not expose this product under high temperature or moisture area.
  • Page 6: Overview

    1. Overview 1.1 Front View MENU DOWN 3 4 5 6 Channel dimmer module...
  • Page 7 1. Overview 1.1 Front View 1. 2x16 LCD Display Shows the current activities or adjustments of menus. 2. DMX LED This LED blinks when DMX signal is present. 3. MENU Button This button is used to access set-up menus. 4. UP Button Tap this button to scroll through menus or to increase values .
  • Page 8: Rear View

    1. Overview 1.2 Rear View Analog in: 0~10VDC DMX IN 1 : Ground 2 : Data - 3 : Data + DMX OUT 23-001-1518 1. Analogue Input DC 0-10V 2. DMX Input This jack is used to receive an incoming DMX signal.. 3.
  • Page 9 1. Overview 1.3 Mains power & Output Termination...
  • Page 10: Operation Guide

    2. Operation Guide 2.1 Display and standby mode Power on this unit, the LCD shows the revision of software immediately, then enter standby mode automatically, the LCD shows the dimming level of each channel as below. The first row indicates the dimming level, and the second row indicates the channel(1 stands for channel 1, 2 stands for channel 2, and so on.
  • Page 11: Dmx Fail

    2. Operation Guide 2.2.1 DMX Fail 2. Tap MENU button again to enter sub-menu Dmx fail system. You can use UP/DOWN button Hold to select Hold/Analog/Prog. 1-12. [Hold]: Last received DMX signal is held. MENU UP DOWN ESC [Analog]: The analogue input(0-10v) is activated. [Prog.
  • Page 12: Phase Correction

    2. Operation Guide 2.2.2 Phase Correction Pha corr 1. Tap UP/DOWN button to scroll to Phase Correction menu. MENU UP DOWN ESC 2. Tap MENU button to enter sub-menu Pha corr system. You can use UP/DOWN button to select Yes/No. [Yes]: Linear dimming is activated.
  • Page 13: Dmx Address

    2. Operation Guide 2.2.3 DMX Address 2. Tap MENU button to enter sub-menu Dmx addr system. You can use UP/DOWN button Block to select Block/Single. [Block]: Complete dimmer(6 channels) has only MENU UP DOWN ESC one start address. [Single]: The DMX address of each channel is selectable, several channels can select the same DMX addresses.
  • Page 14: Preheat

    2. Operation Guide 2.2.3 DMX Address Chan[1] 5. In Single mode, tap MENU to change between [001] the channel and its address. MENU UP DOWN ESC 6. When channel is activated, tap UP/DOWN Chan[1] button to select from [1-12]; when address is [001] activated, tap UP/DOWN button to select from[001-512].
  • Page 15 2. Operation Guide 2.2.4 Preheat 2. Tap MENU button to enter sub-menu Preheat system. MENU UP DOWN ESC 3. Tap UP/DOWN button to select between All/Single mode, and tap MENU to enter All/Single mode. Preheat [000%] MENU UP DOWN ESC MENU UP DOWN ESC 4.
  • Page 16: Curve

    2. Operation Guide 2.2.4 Preheat 6. When channel is activated, tap UP/DOWN Chan[1] button to select from [1-12]; when preheat is [050%] activated, tap UP/DOWN button to select from [000%-050%]. MENU UP DOWN ESC Preheat 7. Tap ESC button to exit. MENU UP DOWN ESC 2.2.5 Curve...
  • Page 17: Preset

    2. Operation Guide 2.2.5 Curve Curve 3. Tap UP/DOWM button to select from Linear/ Linear Switch/Square. MENU UP DOWN ESC Curve 4. Tap ESC button to exit. MENU UP DOWN ESC 5. You can tap ESC button to return to Beginning Menu.
  • Page 18 2. Operation Guide 2.2.6 Preset 2. Tap MENU button to enter sub-menu Preset system. MENU UP DOWN ESC 3. Tap UP/DOWN button to select between All/Single mode, and tap MENU to enter All/Single mode. Preset [000%] MENU UP DOWN ESC MENU UP DOWN ESC 4.
  • Page 19: Technical Specifications

    2. Operation Guide 2.2.6 Preset 6. When channel is activated, tap UP/DOWN Chan[1] button to select from [1-12]; when dimming [050%] level is activated, tap UP/DOWN button to select from [000%-100%]. MENU UP DOWN ESC Preset 7. Tap ESC button to exit. MENU UP DOWN ESC Technical Specifications...
  • Page 20 Printed in PR China All Rights Reserved 24-004-0892 Rev 1.0 October 2002...