Provision For Ventilation - Electrolux EKG 6704 Instruction Booklet

Gas and mixed fuel cookers
Table of Contents

Advertisement

Instructions for the Installer
Installation
This appliance cannot be positioned on a
base.
The following instructions are meant for a qualified
installer, in order that the operations of installation,
regulation, and service are executed according to the
existing regulations.
Whenever changes are mode involving the disconnection
of the appliance it is necessary to proceed with
maximum caution.
THE MANUFACTURING COMPANY DECLINES
ANY RESPONSABILITY FOR POSSIBLE
DAMAGES
RESULTING
INSTALLATION WHICH DOES NOT COMPLY
WITH THE RULES IN FORCE.

Provision for ventilation

This appliance is not connected to a combustion
products evacuation device. It shall be installed and
connected in accordance with the current installation
regulations. Particular attention shall be given to the
relevant requirements regarding ventilation.
The use of a gas cooking appliance results in the
production of heat and moisture in the room in which it is
installed. Ensure that the kitchen is well ventilated: keep
natural ventilation holes open or install a mechanical
ventilation device (mechanical extractor hood).
Installation environnement
Warning - This unit can be installed and can work only
in constantly ventilated rooms, according to rules in
force.
In order to make the gas unit work properly, it is
necessary that air sufficient to gas combustion can
naturally flow in the room. (The installer must follow the
rules in force).
The air flow into the room must come directly through
openings of external walls. These openings (or opening)
should be realized in such a way not to be occluded both
from inside and outside.
Installation and maintenance must be carried out by a
qualified technician, in compliance with rules in force.
The electric coonection must be carried out in
compliance rules in force.
Our responsability will not be involved in case of
accidents caused by a defective or non existent
earth connection.
22
Combustion products discharge
Gas cooking units must discharge combustion products
through hoods directly connected to flues or outside.
Positioning
This appliance has been designed to be placed close to
furniture units not exceeding the height of the working
level.
Levelling
The appliance is provided with adjustable small feet
placed in the back and front corners od the base.
FROM
AN
By adjusting the small feet it is possible to change the
height of the appliance so as to ensure a better levelling
with other surfaces and a uniform distribution of the
liquids contained in pans or pots (Fig. 18) .