Table 4.
Description
AC-input voltage
AC-input frequency
AC-input current
Maximum input VA
Maximum output power per power supply
Maximum inrush current
Maximum heat output
Maximum hold-up time
Power supply output voltage
Efficiency rating
Note:
For configuration specific power specifications, use the Cisco UCS Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Environmental Specifications
Table 5.
Environment
Temperature operating
Temperature nonoperating
Altitude operating
Humidity (RH), noncondensing
Contents:
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Power Specifications for the Cisco UCS 6140XP Fabric Interconnect
AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Environmental Specifications for the Cisco UCS 6100 Series Fabric Interconnects
Specification
0°C to 40°C (32°F to 104°F)
-40°C to 70°C (-40°F to 158°F)
0 to 3,000 m (0 to 10,000 ft.)
5 to 95%, non condensing
Overview
Expansion Module Notes
Power Specs
Specification
90 to 264 VAC
50 to 60 Hz nominal (Range: 47 to 63 Hz)
9.2 Amps @ 90 VAC
828 VA @ 90 VAC
750W @ 12 VDC (up to two power supplies)
35 A <sub cycle duration
2561 BTU/hr
12 ms
12 VDC
89% (Climate Savers Gold qualified)
Detailed Views
Base Unit Features
Accessory Kit Notes
Console Cable Notes
Environmental Specs
Transceiver Specs
Configuring
Services
Physical Specs
Page 28 of 30