on the keypad programming parameters is located in
the following sections.
Zone
Channel
Change
Change
Select
Select
Channel
Zone
Scan Hold Timer
Tx Timer
Penalty Timer
Conver. Timer
F1 = Select
F2 = Exit/Back
Up/Down = Scroll
Figure 6 Keypad Programming Menu Flow-
chart

Zone Password

Each zone can be programmed so that the correct
password must then be entered before system or
channel parameters in that zone can be changed by
keypad programming. A different password can be
programmed for each zone.
When an attempt is made to select a system or
channel parameter in a password protected zone,
"ENTER PSWD" is displayed. The password is
always eight digits long and is entered using the same
procedure as used for the power-up password
described on page 9. After the password is entered,
system and channel parameters for that zone can be
reprogrammed normally.

Zone Change Parameter

The "CHG ZONE" menu parameter selects the
zone containing the conventional channel to be repro-
grammed. It does not change the zone selected for
normal operation.
Channel
System
Parameters
Parameters
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Tmr On-Off
Chan Spacing
Squelch Adj
Tlk Grp Sel
CONVENTIONAL MODE FEATURES
Press the F2 key to select the "ZONE CHG"
parameter and then scroll through the programmed
zones by pressing the Up/Down switch. When the
desired zone is displayed, select it by pressing the F2
key.

Channel Change Parameter

The "CHNG CHAN" menu parameter selects the
conventional channel to be reprogrammed. Disabled or
SMARTNET/SmartZone channels cannot be selected.
This does not change the channel selected for normal
operation.
Press the F2 key to select the "CHNG CHAN"
parameter and then scroll through the programmed
channels by pressing the Up/Down switch. When the
desired channel is displayed, select it by pressing F2
key.

System Parameters

NOTE: If "ENTER PSWD" is briefly displayed when
attempting to select a parameter, see Zone Password
description on page 21.
The "SYS PARMS" menu parameter selects the
conventional mode timers to be reprogrammed (see
following). Press the F2 key to select the "SYS
PARMS" parameter and then press the Up/Down
switch to display the desired parameter. Then press the
F2 key again to select it.
SCAN TIMER - Selects the Scan Hold timer. Press the
Up/Down switch to decrement/increment the timer in
0.5-second steps, or set it to 0 seconds to disable it.
When the desired value is displayed, store it by
pressing the F2 key.
TX TIMER - Selects the transmit time-out timer. Press
the Up/Down switch to decrement/increment the timer
in 15-second steps, or disable it by selecting 0
seconds. When the desired value is displayed, store it
by pressing the F2 key.
PEN TIMER - Selects the penalty timer. Press the Up/
Down switch to decrement/increment the timer in 15-
second steps. When the desired value is displayed,
store it by pressing the F2 key.