TYPE OF GAS
NOMINAL THERMAL
POWER
NATURAL GAS
20 mbar
NOMINAL FLOW
VALUE =
RATE
37.78 MJ/m
3
NOZZLE REFERENCE
Ws - 50.7 MJ/ m
3
NOMINAL THERMAL
LPG GAS
POWER
28-30/37 mbar
NOMINAL FLOW
VALUE =
RATE
49.92 MJ/Kg
NOZZLE REFERENCE
Burner
Auxiliary
Semi-rapid
Rapid
Aeration adjustment none
BURNER
POSITION
kW
3
m
/h
1/100 mm
kW
g/h
1/100 mm
Dia. Tap By-pass
1/100 mm
28
32
42
RAPID
SEMI-RAPID
(large)
(medium)
M A X
MIN
M A X
3.0
0.75
2.0
0.286
0.057
0.190
119
Adjust.
96
2.8
0.75
2.0
202
43.5
144
86
42
71
AUXILIARY
(small)
MIN
M A X
MIN
0.45
1.0
0.33
0.038
0.095
0.028
Adjust.
70
Adjust.
0.45
1.0
0.33
29
72
21,5
32
50
28
11

Advertisement