Control Valves - AEG 24968 G-m Use, Installation And Maintenance Instructions

Built-in hot plates
Table of Contents

Advertisement

Warning:
Adjustment of this appliance shall only be
carried out only by authorised personnel.
9) BURNERS
PRIMARY AIR ADJUSTMENT (refer figure 18)
- Turn off power and unplug electric lead from
power point.
- Remove the knobs "M".
- Unscrew the screws "V".
- Lift the control panel.
Ignite the burners and adjust the sleeves "B" (refere
figure 19 and table in the next page) to obtain the
desired flame. Ensure that locking screws "A" are
retightened.
FIG. 18
REGULATION

10) CONTROL VALVES

"Reduced rate" adjustment
The control valves are suitable for all types of
gases.
They are the male cone type allowing one direction
of flow.
Simmer flame adjustment (refer figure 20)
- Light burner and set to low setting.
- Remove control knob (friction fit).
- Insert a small screwdriver into the hollow stem of
the valve and adjust the flame to the desired level.
- Ensure that flame is stable when the controls are
rapidly moved from low to maximum.
NOTE:
Adjustment may be necessary when the
appliance is connected to Natural Gas. When
connected to LPG the valve cone should be
screwed down completely.
FIG. 19
8
FIG. 20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

24658 g-m

Table of Contents