Trouble Shooting Guides continued
LCD User Screen Display Information
Display Reads
E01
E02
E04
E05
Dry
Lid
Problem
Sensor malfunction
Pressure can not gain
Temperature is too high.
Dry Error. There is not
enough liquid in the pan
Lid Error. The lid is
locked using the frypan
menu
Solution
Contact Sunbeam Customer Service on
Australia 1300 881 861
New Zealand 0800 786 232
Ensure the lid is locked on, and the pressure
valve is in the 'SEAL' position.
If this error still occurs, ensure the gasket
and the valves are clear from debris. Then
reset the unit.
Open the lid and allow to cool. After the mes-
sage disappears, relock the lid, ensure the
valve is in the 'SEAL' position and reset the
program.
Carefully use the finger tab on the pressure
release valve and flick to 'RELEASE'. When
pressure has been released, carefully remove
the lid using oven mitts and add liquid to the
pan. Replace and lock lid, and ensure the
valve is in the 'SEAL' position.
Do not lock the lid on the frypan menus.
Remove the lid and reset the program.