Recommended Installation Locations - Kidde KN-COB-B-LPM User Manual

Carbon monoxide alarm
Hide thumbs Also See for KN-COB-B-LPM:
Table of Contents

Advertisement

2. Product Features and Specifications
Temperature:
Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
Humidity:
Operating range: 10-95% non-condensing
Audible Alarm:
85+ dB at 10' @ 3.4±0.5 KHz pulsing alarm
Sensor:
Electrochemical
Power:
3-AA Batteries
Accuracy of Digital Display: (Model KN-COPP-B-LPM Only)
30-999 PPM +/-30% when measured in conditions of 80° F (+/- 10°
F), atmospheric pressure +/- 10% and 40% +/- 3% relative humidity.
Display readings may vary slightly depending on changes in the ambient
condition (temperature, humidity) and the condition of the sensor.
Alarm Response Times:
70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.
3. Installation Locations

Recommended Installation Locations

CO alarms should be mounted in
or near bedrooms and living areas.
It is recommended that you install
a Kidde CO alarm on each level of
your home.
When choosing your installation
locations, make sure you can hear
the alarm from all sleeping areas. If
you install only one CO alarm in your home, install it near bedrooms,
not in the basement or furnace room.
• When wall mounting, place out of reach of children. Under no
circumstances should children be allowed to handle the CO alarm.
• Placing the alarm at eye level allows for optimum monitoring of the
digital display.
KITCHEN BEDROOM BEDROOM
DINING
LIVING ROOM
Recommended Locations
BEDROOM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kn-copp-b-lpmKn-copp-b-lpmKn-cob-b-lp

Table of Contents