5. Model KN-COB-B-LPM Operating Characteristics
Whenever the alarm is operating, the green Power LED flashes every 30
seconds to indicate the unit is monitoring for CO. If the alarm senses
dangerous levels of CO, the red Alarm LED will flash and the alarm will
emit an audible alarm pattern.

Operating and Alarm Characteristics

Function
LED Display
Normal
Green LED
Operation
flashes every 30
seconds
Carbon
Red LED flashes
monoxide
with beeps.
alarm
Low
Red LED flashes
battery
every 60 seconds
Error /
Red LED flashes
service
every 30 seconds
alarm
Error
Red LED
constantly on
Normal
Red LED flashes
Test/Reset
with beeps.
function
End of
Red LED flashes
unit life
two times
indicator
every 30 seconds
6. Model KN-COPP-B-LPM (with digital display)
Operating Characteristics
When the unit is first powered up, the green Operate LED flashes
once every 30 seconds and the digital display will show three "eights"
– indicating the alarm is in the start-up mode. The three "eights" will
remain for approximately 30 seconds. Then, the alarm will display "0"
and begin monitoring the air for CO and will continue to do so as long
as it receives power.
This alarm will display a "0" if CO concentrations between 0 and 30
PPM have been detected within the last 15 seconds.
Alarm Sound
Unit Status
None
Normal DC
operation (sensing
no CO) and with
good batteries
4 quick beeps,
Alarm condition.
5 seconds
Dangerous con-
silence,
centrations of CO
repeating
detected
One quick
Batteries need to be
beep every
replaced
60 seconds
One quick
Unit is in error
beep every
condition
30 seconds
Constant
Very low battery or
alarm
unit malfunction
4 quick beeps,
Normal operation
5 seconds
when Test/Reset
silence,
button is pressed
repeated once
Two quick
End of unit life
beeps every
30 seconds
Recommendation
None
Refer to "What to
do When the Alarm
Sounds" (inside front
cover)
Replace all three AA
batteries
Replace battery.
If condition continues,
unit has malfunc-
tioned. Replace
immediately. Unit will
not respond to CO
CO not detected.
Alarm for test pur-
poses only
Replace unit imme-
diately. Unit will not
respond to to CO