Instructions For The Installer; Engineer Technical Data - AEG 65402 G Instruction Booklet

Hide thumbs Also See for 65402 G:
Table of Contents

Advertisement

Instructions for the Installer

Engineer technical data

OVERALL DIMENSIONS
CUT OUT DIMENSIONS
SUPPLY CONNECTIONS
fuse.
HEAT INPUT
Rear Left Burner
(semi rapid)
Front Left Burner
(semi rapid)
Rear Right Burner (Mod. 65852)
(triple crown)
Rear Right Burner (Mod. 65402)
(rapid)
Front Right Burner
(auxiliary)
APPLIANCE CLASS
APPLIANCE CATEGORY
GAS SUPPLY
This appliance is manufactured according to the following EEC
directives:
2006/95 EEC - 93/68 EEC - 89/336 EEC - 90/396 EEC,
current edition.
Width:
594 mm
Depth:
510 mm
Width:
560 mm
Depth:
480 mm
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
~
230 V
50 Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge
2.0 kW (6826 BTU/HR)
2.0 kW (6826 BTU/HR)
4.0 kW (13652 BTU/HR)
3.0 kW Natural Gas (10239 BTU/HR)
2.8 kW LPG (9556 BTU/HR)
1.0 kW (3413 BTU/HR)
3
II2H3+
Natural gas G20 (2H) / 20 mbar
13