Advertisement

Current Pending Sector
Test Type
Test Result
Test Time

Bad Block Scan

On the Disk Information screen, select a disk then click on "Detect Bad Block" to perform bad block
scan of the associated disk. The result is only for reference and the system will not take any action
from its results.
The bad block scan can be terminated by clicking on "Stop Detect Bad Block".
3.4.2

RAID Information

From the Storage menu, choose the RAID Management item and the RAID Management screen ap-
pears.
This screen lists the RAID volumes currently residing in the Thecus IP storage. From this screen, you
can get information about the status of your RAID volumes, as well as the capacities allocated for
data.
RAID Information
Item
Master RAID
ID
Chapter 3: System Administration
26
Current count of unstable sectors (waiting for remapping). The raw value of this attribute indicates the
total number of sectors waiting for remapping. Later, when some of these sectors are read successfully,
the value is decreased. If errors still occur when reading sectors, the hard drive will try to restore the
data, transfer it to the reserved disk area (spare area), and mark this sector as remapped. If this attribute
value remains at zero, it indicates that the quality of the corresponding surface area is low.
Set short or long time to test.
Result of the test.
Total time of the test.
Description
The RAID volume currently designated as the Master RAID volume.
ID of the current RAID volume.
NOTE: All RAID IDs must be unique.