Cleaning And Care; 18 Series Maintenance - Delta Jetted Shower Installation Instructions Manual

Single handle monitor multichoice
Table of Contents

Advertisement

Available languages

Available languages

Cleaning and Care

Care should be given to the cleaning of this
product. Although its finish is extremely du-
rable, it can be damaged by harsh abrasives
or polish. To clean, simply wipe gently with a
damp cloth and blot dry with a soft towel.

18 Series Maintenance

Cannot receive more than a trickle of water:
Both hot and cold supply lines must be
pressurized. If only one side is pressurized, the
pressure balance system will not allow adequate
flow of water.
Volume control handle rotates 360
degrees or is not positioned correctly per
escutcheon, (sleeve is also loose). The keys
of the cartridge have not been properly placed
in the keyways in the brass body or keys on
cartridge have been sheared off due to improper
installation. BE SURE TO CORRECT THIS
SITUATION IMMEDIATELY.
Cannot receive enough hot water:
See step 3 and/or check water
heater temperature.
Faucet leaks from tub spout/showerhead:
SHUT OFF WATER SUPPLIES. Replace
Adapter Assembly –Repair Kit RP46073.
If leak persists–
SHUT OFF WATER SUPPLIES
Replace cartridge assembly–RP46463.
Unable to maintain constant water
temperature:
SHUT OFF WATER SUPPLIES. Remove
cartridge assembly, shake cartridge side to
side. Spool should rattle in sleeve. If rattle
cannot be heard, spool may be stuck. Spool
may be freed up by rapping cartridge briskly
sideways into the palm of your hand. If spool
cannot be freed, replace cartridge assembly–
RP46463.
NOTE: If the water in your area has lime, rust,
sand, or other contaminants in it, your pressure
balance valve will require periodic inspection.
The frequency of the inspection will depend on
the amount of contaminants in the water. To
inspect cartridge, remove it from the body and
shake it rigorously. If there is a rattling sound,
the unit is functional and can be reinstalled
in its previous position. If there is no rattle,
replace the cartridge with RP46463.