Summary of Contents for UCONNECT INTERNATIONAL RS-232
Page 1
Total Package Weight: 110 g 1. Packing Contents 1. Packing Contents 1.1 BT-232B Package Contents: 1.1BT-232B-E Package Contents: RS-232 adapter x 1 RS-232 adapter x 1 Battery power line and connector x 1 Battery power line and connector x 1 User manual x 1...
Page 2
Mini USB (Power In) Reset Pin Hole Power Source Switch DEC/DTE Switch Power Line Connector 3.4 Check the RS-232 setting on 2 sides if they both have the following values: Baud rate: 19200 bps Data bit: 8 Parity: none Stop bit: 1...
Page 3
User Manual V2.4 Date: 2011.04.20 How to use external battery Standard A, AA or Li-Polymer Battery: 3~3.7 VDC. AAA battery: 3 units for The capacity depends on the each model. applications. General working power consumption: 100 mAh (for reference) Factory Settings for COM port and Bluetooth: Baud rate: 19200 bps Data bit: 8 Parity: none...
Page 4
Check the connection status between control terminal and the RS-232 adapter. Response: “OK” when the connection is ok. Response: “ERROR” when the connection is not ok. Test the RS-232 status when first connect the adapter with the controller. AUTO= This command is used to enable/disable auto-connection feature. It is available only when the adaptor is in the master role.
Page 5
User Manual V2.4 Date: 2011.04.20 921600 921600 bps Restore the default settings. (Baud rate =19200 bps) Inquire the current baud rate. CONNECT= This command is used to establish a connection manually. It is available only when the adaptor is in the master role. DEVICE Connect the adaptor to a specified Bluetooth device manually.
Page 6
User Manual V2.4 Date: 2011.04.20 cannot discover this adaptor. (Default) The adaptor enters the discoverable mode. Inquire the current setting. ECHO= This command is used to specify whether the adaptor echoes characters received from the UART back to the DTE/DCE. Command characters received from the UART are not echoed back to the DTE/DCE.
Page 7
User Manual V2.4 Date: 2011.04.20 RECONNECT= The command is used to re-connect the lost link for the Master adapter. Inquire the current setting. (Default) Re-connect is disable Re-connect is Enable ROLE= This command is used to specify whether the adaptor is in the master or slave role.
User Manual V2.4 Date: 2011.04.20 13. RS232 Interface 13.1 Pin-out: 13.2 Signals: Signal DTE Direction DCE Direction Description Output Input Not connected Input Output Transmitted data Output Input Received data Output Input Contact manufacturer to set this Signal ground Input Output Contact manufacturer to set this Output...