Majestic fireplaces GBR36 Series Homeowner's Installation & Operating Manual page 14

Gbr series b-vent gas fireplace
Hide thumbs Also See for GBR36 Series:
Table of Contents

Advertisement

GBR Series B-Vent Gas Fireplace
Warning:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury and loss of life.
FOR YOUR SAFETY READ THE FOLLOWING WARNINGS
A. This fireplace is equipped with an ignition device
which automatically lights the pilot. DO NOT try to
light the pilot by hand.
B. BEFORE OPERATING, smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than the air
and will settle on the floor.
What to do if you smell gas
• Do not try to light any appliance
• Do not operate any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
1. STOP! Read the safety information above before
continuing.
2. Turn off all electrical power to the appliance.
3. This appliance is equipped with an ignition device
which automatically lights the pilot. DO NOT try to
light the pilot by hand.
4. Access the gas control by lowering the lower
access door (louvre assembly).
HI
1. Turn the remote switch to the "OFF" position.
2. Turn OFF all electrical power to the fireplace if
service is required.
3 Open the lower access panel.
4. Turn the shut-off valve on the flexible gas line
to the "OFF" position.
14
Lighting and Operating Instructions
For Fireplaces equipped with SIT822 Gas Valve (EN or EP)
BEFORE LIGHTING THE APPLIANCE
Lighting Instructions
Turning Off the Gas to the Appliance
Follow the gas suppliers instructions.
• If you cannot contact your gas supplier call
the Fire Department
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in
or turn by hand do not try to repair it, call a qualified
service technician. Force or attempting repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and replace any part of the
control system and any gas control that has been
under water.
5. Turn the remote switch, if used, OFF. Turn the
wireless remote, if used, OFF.
6. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas STOP. Follow instructions B in the safety
warnings above. If you do not smell gas go onto the
next step.
7. Close the access door.
8. Turn ON all electrical power to the appliance.
9. Turn remote switch or wireless remote to "ON".
10. If the appliance will not operate, follow the
instructions TURNING OFF THE GAS TO THE
APPLIANCE and call your service technician or
gas supplier.
1/2" Gas Supply
1/2" x 3/8" Shut-off Valve
Valve in the "ON" position
GF598
nvb GAS SUPPLY INSTALL
12/4/97
3/8" Nipple
3/8" Union
3/8" Nipple
FP297A
7412955

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gbr36rnGbr36rpGbr36enGbr36ep

Table of Contents