Contact Reverse Test; Open/Close Travel Limit - Genie 2024 User Manual

Includes: 2-bulb light system wall console
Hide thumbs Also See for 2024:
Table of Contents

Advertisement

UP/DOWN FORCE
1. By turning the "Close Force Control"
wise, the DOWN force can be increased. By
turning the "Close Force Control"
clockwise, the DOWN force can be decreased.
Set the DOWN force level at the minimum force
required to close door without reversing.
2. Once the desired level is selected, this stores the
necessary force level for the DOWN direction in memory.
3. By turning the "Open Force Control"
the UP force can be increased. By turning the
"Open Force Control"
force can be decreased. Set the UP force level at
the minimum force required to open door without
stopping.
4. Once the desired level is selected, this stores
the necessary force level for the UP direction
in memory.
ERASE - OPEN/CLOSE TRAVEL LIMIT
1. Press and hold both of the "SET" buttons
( & ) together until the green indicator
SET
SET
light blinks (about 5 seconds).
2. All close and open travel limit settings are
erased. Then follow the steps above to
reprogram close and open travel limits.
NOTE: The opener will not close the door
automatically unless the Safe-T-Beam
installed.

CONTACT REVERSE TEST

The force adjustments and limit switch settings
MUST BE COMPLETED before testing.
1. Testing.
• Open garage door using Wall Control.
– Place a 2" x 4" board (laid flat) under center
of garage door opening (FIG. 6-6).
• Close door using Wall Control.
• When door contacts board, the door must stop
(within 2 seconds) and reverse direction
returning to open position.
2. Adjustment.
• If the door does not properly reverse.
– Check to see if door has "close" limit
programmed. It should not have reached its
"close" limit before hitting board.
– If the door STOPS but does not reverse,
decrease "CLOSE FORCE" control
setting slightly (turn it counter-clockwise).
• Test again. Repeat as necessary until door
reverses upon contacting board.
22
clock-
CLOSE
counter-
CLOSE
OPEN
clockwise,
OPEN
counter-clockwise, the UP
®
System is
CLOSE
PN# 37026500123
Up Force
Control
OPEN
Adjustment
FORCE
CLOSE
Down Force
Control
Adjustment
FIG. 6-5
Force Control Adjustment.
FIG. 6-6
2 x 4 under center of door opening.
02/26/2010 REV. 1
(Increasing Force)
ROTATE
CLOCKWISE
(Decreasing Force)
ROTATE
COUNTER-CLOCKWISE