Download Print this page

Generac Power Systems Liquid Cooled Gas Engine Generator Sets None Specification Sheet page 3

130 kw 60 hz liquid cooled gas engine generator sets commercial series

Advertisement

COMMERCIAL 130 kW
OPERATING DATA
KW RATING
ENGINE SIZE
GENERATOR OUTPUT VOLTAGE/KW - 60Hz
120/240V, single phase, 1.0 pf
120/208V, 3-phase, 0.8 pf
120/240V, 3-phase, 0.8 pf
277/480V, 3-phase, 0.8 pf
GENERATOR LOCKED ROTOR KVA
AVAILABLE @ VOLTAGE DIP OF 35%
Single phase or 208V & 240V 3-phase
480V 3-phase
ENGINE FUEL CONSUMPTION
(Natural Gas) (Propane)
Exercise cycle
25% of rated load
50% of rated load
75% of rated load
100% of rated load
ENGINE COOLING
Air flow
(inlet air including alternator and combustion air)
System coolant capacity
Heat rejection to coolant
Max. operating air temp. on radiator
Max. ambient temperature
COMBUSTION AIR REQUIREMENTS
Flow at rated power 60 Hz
SOUND EMISSIONS IN DBA
db(A) @ 23 feet in exercise mode
db(A) @ 23 feet at normal operating load
EXHAUST
Exhaust flow at rated output 60 Hz
Exhaust temp. at muffler outlet
ENGINE PARAMETERS
Rated synchronous RPM
HP at rated KW
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
Temperature Deration
Altitude Deration
RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility
source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and
specifications are subject to change without notice. Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power
and condition, etc.
ft 3 /hr.
US gal.
BTU/hr.
°C (°F)
°C (°F)
cfm
cfm
°F
60 Hz
60 Hz
3% for every 10 °C above - °C
1.65% for every 10 °F above - °F
1% for every 100 m above - m
3% for every 1000 ft. above - ft.
COMMERCIAL 130 kW
130
6.8 Liter V-10
KW
AMP
130
541.6
130
451.5
130
391.3
130
195.6
270
320
Natural Gas
(ft 3 /hr.)
(gal/hr.)
135
1.48
482
5.28
927
10.15
1292
14.15
1786
19.56
6,450
4.5
496,000
60 (150)
50 (140)
336
65
75
1,119
970
3000
210
25
77
183
600
COMMERCIAL SERIES
CB Size
600
500
450
225
Propane
cu ft/hr
54.5
194.3
373.5
520.7
719.8

Advertisement

loading
Need help?

Need help?

Do you have a question about the Liquid Cooled Gas Engine Generator Sets None and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Guardian elite whisper-test