Specifications - Radio Shack 22-813 Owner's Manual

29-range auto/manual digital multimeter
Table of Contents

Advertisement

The meter contains a 5
20mm, 500mA,
250V ceramic fuse (Radio Shack Cat. No.
o
270-1070).
1. Set the function dial to
the test leads.
2. Use a Phillips screwdriver to loosen
both screws on the back cover of the
meter. Then lift off the cover.
3. To remove the fuse, gently pull the red
ribbon wrapped around it. The fuse
pops out.
4. If the fuse is blown, discard it and save
the red ribbon. Then remove the supplied
spare fuse, slip it into the ribbon, and
insert the fuse into the fuse holder.
5. Replace the back cover of the meter
then secure it with the screws.

SPECIFICATIONS

Accuracies at 23°C ± 5°C, < 75% RH.
DC VOLTS (Maximum Measurement: 600V)
400mV .................................... ± 0.5% of Reading,
4V
40V
400V ................... ± 0.8% of Reading,
600V ....................................... ± 1.0% of Reading,
AC VOLTS (600 V RMS Maximum at 50/60Hz,
Average responds, RMS calibrated, DC Coupled)
400mV .................................... ± 1.2% of Reading,
4V ........................................... ± 0.8% of Reading,
40
400V
600V .................. ± 1.2% of Reading,
o
WARNING
To avoid electric shock,
you must disconnect the
and unplug
OFF
test leads before you
remove the back cover.
Do not operate your
meter until the back
cover is in place and
secured.
± 4 in Last Digit
± 4 in Last Digit
± 4 in Last Digit
± 5 in Last Digit
± 5 in Last Digit
± 5 in Last Digit
o
21

Advertisement

Table of Contents
loading

Table of Contents