Page 1
( ® radioshack 2200087 User's Guide True Multimeter Digital Note: The supplied ferrite cable with must be used with multimeter to your ensure compliance Class with (Section limits 15.27). read True Digital Multimeter from RadioShack. Please this hope you enjoy...
Contents Package Contents Contents Features Safety Precautions Special Panel Markings Care and Maintenance SEER UUID ners savas nswos tssasonsebasebsenssstesiass Front View... Basic Operation Auto Power Off....Select a Function and Range Mentor Feature: ..amsmmssssassass Measuring DC/AC Voltage. Current. Measuring DC/AC Resistance.
Contents Package Test Leads Multimeter Digital « « PETER Rubber Boot Cable Thermocouple K-type « — «User's meter) inside Guide Fuse 250V/12A » meter) inside Fuse 250V/500maA « Features Measures voltage, current, resistance, capacitance. frequency, temperature, « more voltage and current readings more accurate True manual-ranging override...
Safety Precautions safety Read follow these precautions. Contents Never apply that voltages to limits meter exceed givenin specifications. Never apply more than 1000V 750V between input jacks ground. extreme caution when working with voltages above 100V. Always from disconnect test circuit you are measuring before power...
Special Panel Markings of electric shock! Refer complete CAUTION: Risk S3Ud3U0) operating instructions. when careful CAUTION: extremely making high- voltage measurements; DO NOT TOUCH TERMINALS PROBE ENDS. double insulation. meter protected that meter can maximum voltage measure this [tage this that 750V—...
Page 6
Setup Install Batteries Remove rubber boot attached ifit off your meter. Loosen Turn screw and remove battery cover. Insert two batteries (not supplied), matching marked polarity symbols inside. Secure battery cover with screw. Battery Notes: fresh batteries of the Useonly required size recommended type.
Page 7
Connect Test Leads Remove before plastic plugs test leads. using your 2. Slide up Sliding Guard the test show sockets. lead test black into lead Plug ~COM (common), then plug test +V.mA.Q. lead into measure current higher than test 400maA, lead into plug instead of +V.mA.Q.
Front View Indicates auto range mode. The meter automatically enters auto range mode turnit when £=%V/dBm Measures volts. voltage °C/°F Measures Celsius or Fahrenheit. temperature Setup HA/A/= Measures current. mA/A/= Measures current. Qrit Measures ohms capacitance. Checks continuity diodes. Hz/LOGIC Measures / frequency.
Page 9
HOLD Tests display. « Disables auto power-off. « Pauses/continues measurement monitoring « (maximum/minimum values). SELECT between measurement options Toggles within a function. RANGE Selects auto or manual ranging. « Selects different ranges manual range mode. « RELA relative measurements. Takes Hz/DUTY/WIDTH Measures frequency, duty cycle, and...
Basic Operation Auto Power left unattended, your meter automatically turns after 30 minutes. Press When button to turn meter back disable auto power off function: Turn off your meter. Pressand hold HOLD and SELECT buttons simultaneously, then turn on meter. PLoc release both buttons.
Page 11
Read volts, ohms, capacitance, or amps as indicated range position point. decimal ddd.d dddd 6000 ddd.d kQ d.dddv dd.dd 60 mA d.ddd dd.ddv ddd.d dd.dd 600V dddd ddd.dVv d.ddd dddd dd.dd nF 1000VvDC 9dddV ddd.dQ ddd.d nF /750V d.ddd kQ d.ddd pF ddd.d 60kQ...
Page 12
DC/AC Measuring Voltage can measure voltage superimposed on voltage source bias while that voltage, but to measure voltage ignoring never riding on a where voltage exceeds bias to earth source peak 1000V with respect ground. above 1000 WARNING: Do to measure a DC voltage volts oran...
do not the amount of know circuit Ifyou current are measuring, always test connect the red lead +10A MAX. Rotate function pA/A/== for 600/6000pA 6/10A ranges or to dial mA/A/== for 60/400mA 6/10A ranges. Press to measure current SELECT current appears) or disappears).
Page 14
Goll Note: resistance connected across the With leads test resistance (meaning infinite), when resistance. appears measure normal. This is Ifyouare measuring resistance of about 1MC) more, display might take a seconds to stabilize. This is normal Tocalculate and measure a very small resistance, see Relative “Taking...
leads Touch test want to measure. across circuit you Shrt buzzer sounds resistance less than circuit appears about 50 ohms (meaning continuous or shorted). circuit Open meter's buzzer does not sound resistance appears circuit greater than about 50 ohms (meaning not continuous).
Measuring Logic more than WARNING: 5V DC between apply terminals. could This damage the meter tested. circuit being Rotate function Hz/LOGIC. dial Press SELECT once. appears. the test Connect leads to device you want check. (the voltage appears is low than logic lower...
select frequency function, press Hz/DUTY/WIDTH kHz, or until Hz, appears. select the function, press Hz/DUTY/WIDTH duty or pulse width cycle % appears select duty until mS appears until pS or select cycle) pulse width). pS, or appears and want select frequency function again, press Hz/DUTY/WIDTH...
Advanced Operation can use supplied cable connect meter to your computer, allowing you monitor, record, and log data over period of time. use your even meter oscilloscope information on display computer. your example, can record changes temperature in a refrigerator or voltage changes circuit period of...
Turn on your meter. Press and hold SELECT together. RANGE [SEN] appears. Start Click icon, click drop-down menu, then click Start button to meter to work with your Data computer. transmitted from your meter computer. The your display you meter also appears on your computer.
Baseline Reference Using a Abaseline allows reference you to compare components directly. example, can compare resistors resistor measuring baseline then measuring how closely resistors match remaining baseline. Select function (not °C/°F, dBm, DF, LOGIC, hg). Press select RANGE range Connect test leads to component whose measurement...
Touch thermocouples probe object want to test. Wait until reading stabilizes. Note: coolant the metal head Apply thermocouple's probe to quicken process of temperature detection. When device's temperature above 140°F (60°C), remove the thermocouple reading stabilizes. The once thermocouple cannot work high temperature...
Additional Information Specifications Accuracies are at 73.4°F (23°C) +5°, <75% DC VOLTS (Maximum Measurement: 1000V, normal ratio: mode rejection >60d8 60Hz) 600MV ..c..20.3% of last reading, +4 ooo. digit 6V,60V +0.3% comms last reading, +3 digit BOOY 55st. +0.5% reading, last digit...
Page 23
CAPACITANCE women +3.0% reading, +40 digits in last wooo. +3.0% last reading, +10 digits B00NF, BUF, £2.0% last reading, +4 digit Note: Accuracy with film capacitor or better, specified from 9.5% scale to full scale except 4.0nF range full from 0.5nF scale.
Page 24
DIODE MODE otto Nominal Current. -.1.0MA =0.6V. 1.1mA @ 0.000V (short), 0.0mA @ =3.2V (open) OVEI=TaNGE >3.0 VDC Vee (max) LOGIC MODE Min. High-Level Voltage Max. Low-Level Voltage OVEN] wren CONTINUITY BEEPER swam. ConbiNULY £50+10Q cece Open .>50210Q OREN CINCH sewsussssresmmmseoemmiesmmsns <1L.oV Short...
This device may following not cause harmful interference, and this device must interference accept any received, including interference that cause undesired operation. Product True Multimeter Digital Model 2200087 RadioShack Responsible Party RadioShack Circle Fort Worth, 76102 Phone 817-415-3200 > °...
Limited Warranty RadioShack warrants this product against defects materials workmanship under normal use original purchaser days after ninety (90) date of purchase from RadioShack-owned store or authorized RadioShack franchisee or dealer. RADIOSHACK NO OTHER EXPRESS MAKES WARRANTIES. does This failure warranty cover: caused...
Page 27
states Some allow limitations on how long an implied warranty lasts exclusion limitation of incidental or consequential damages, so above limitations or exclusions apply you. This warranty gives you specific rights, also legal have other rights you may which vary from state state...
Need help?
Do you have a question about the 2200087 and is the answer not in the manual?