Dear Sir/Madam We thank you for purchasing this Pinguino appliance and congratulate you on your wise choice. Please make the time and effort to read this manual carefully. Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities, during both installation and actual use.
GENERAL DESCRIPTION The PAC26Super is an extremely versatile air-conditioner, performing its air cooling function through either water condensation or air condensation. The user can choose between the two functions: 1) WATER FUNCTION - For economical, highly efficient and rapid air cooling. This function is recommended when the appliance is first switched on and the environment is particularly hot.
DESCRIPTION OF MAIN FEATURES Tab.3 Air outlet grid Programmer (timer) Control panel (press to open) Water container Castors Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Warranty envelope Exhaust hose compartment Power cable compartment Handle Water collecting tray drainage tube...
DESCRIPTION OF ACCESSORIES Tab.4 PARTS DESCRIPTION SUPPLIED Exhaust hose Stopper + flange Castor stop De-scaling fluid Window nozzle Suction cup set ACCESSORY CHECK Check that all parts listed in Table 4 are included.
When installed permanently, all air discharged from the rear hose is extracted from the room in which the PAC26Super is installed. Check that the room (particularly if it is small) is not “air-tight”; a drop in pressure could cause a malfunction and thereby activate the safety switch.
Height of outlet: within the range indicated by the dotted line in the figure below. When the unit is not in use, the outlet hole should be sealed with the stopper supplied. Temporary installation: The outlet holes can be connected in a number of ways: fixed hook In any event, for maximum cooling efficiency the window should be closed as much as possible.
PREPARING THE UNIT FOR USE 1) Fit the exhaust tube in place; if your conditioner is supplied with a bayonet tube, it is fitted as illustrated in the diagram. 2) For permanent installation, place the appliance near the wall or window outlet. Make sure it is standing on a level surface and fit the special shock absorbers/castor stops underneath the castors.
AIR COOLING FUNCTION If the air cooling function of PAC 26 Super is chosen, it is sufficient not to fill the water container. FINAL CHECK In order to obtain maximum performance from your air-conditioner, make sure that: — doors and windows in the room to be air-conditioned are closed (with the sole exception of the partially opened window necessary for “temporary”...
CONTROL PANEL Signal lamp indicating 3 min.wait (flashing) or air-cooling (on continuously) Plot lamp mains (continuous light) or malfunction (flashing light) Max. air-cooling ON/OFF Timer key warning light ON timer signal lamp Min. air-cooling warning light Air-cooling key TIMER ON MEMO CONTROL THERMOSTAT Ventilation key...
Page 10
HOW TO START UP THE CONDITIONER (see control panel on the opposite page) Plug the appliance into the mains. The signal lamp will come on Press the ON/OFF key. signal lamp goes The function signal lamps flash and the out. Press the key for the function required: AIR-COOL.
SPECIAL PRECAUTIONS — The appliance must be earthed as indicated in the installation instructions. The manufacturer will not accept responsibility for any damage arising if these safety regulations are not complied with. — If the power supply cable is replaced, use only type HO5VV-F, 3x1 mm diameter cables.
SERVICING PRECAUTIONS: during cleaning and normal maintenance operations, remember to disconnect the plug. Under no circumstances should the appliance be washed with running water. Damage could be caused to the electrical circuit. AIR-FILTER CLEANING — A clogged air filter reduces air circulation and the efficiency of the appliance. Clean the filter once a week.
TROUBLESHOOTING A malfunction or defect may only be the result of a minor problem which can be easily resolved without assistance. Look through this checklist therefore, before contacting the Authorised Service Centre operating in your area. PROBLEM CAUSE REMEDY The air-conditioner •...
Page 14
Periodic Servicing (IMPORTANT) This appliance should be de-scaled whenever the calcium deposit becomes excessive (on average after 400 operating hours) or in any event at least once every season. INSTRUCTIONS FOR DE-SCALING You will need: 1/4 liter de-scaling fluid (supplied with appliance) 1 liter clean water = 80% dilution a) Remove the container from the unit and drain away any water left in the collecting...