Advertisement

GB-5751010700
15-01-2004
I m p o r t a n t s a f e g u a rd s
• Use this appliance only as described in this instruction manual.
As with any electrical appliance, whilst the instructions aim to cover as
many eventualities as possible caution and common sense should be
applied when operating and installing this air conditioner.
• This appliance has been manufactured to cool and de-humidify
domestic environments and should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in line with the relevant national legi-
slation.
• Should repairs be necessary, contact the nearest authorised Repair
Service Centre. Unauthorised servicing can be dangerous.
• This appliance is to be used by adults only; keep away from children.
• In the case that the power cable becomes damaged, this must be sub-
stituted only by specialised personnel authorised by the manufacturer.
• Always ensure the appliance is earthed. If you have any doubts check
with a qualified electrician.
• Avoid using extension leads with the unit.
• Before cleaning or maintenance operations, always unplug the unit
from the socket.
• Do not pull on or place strain on the power cable when moving the
appliance.
• The appliance should not be installed where the atmosphere may
contain combustible gases, oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects onto the appliance.
• Remember to perform the descaling procedure at the end of each
season (see page 25). In areas where the water is particularly hard
(rich in minerals), the use of a commercial anti-lime product added to
the water is recommended. This can be requested from De'Longhi
LTD.
• Clean the filters at least once a week.
• Avoid using heaters near the unit.
The unit should be transported in a vertical position. If this is not
possible secure the unit at an angle, do not lie horizontally.
• Before transporting the unit drain the condensation collecting-tray
and tank. After transportation, wait at least 1 hour before switching on
the unit.
• The packaging materials can be recycled. You are therefore recom-
mended to place them in the special containers for differentiated
waste collection.
• R407 refrigerant respects the EEC ecological norms anyway we
recommend you do not perforate the refrigerant circuit of the
appliance.
16
16:32
Pagina 16

Advertisement

Table of Contents
loading

Summary of Contents for DeLonghi PAC 46

  • Page 1 GB-5751010700 15-01-2004 16:32 Pagina 16 I m p o r t a n t s a f e g u a rd s • Use this appliance only as described in this instruction manual. As with any electrical appliance, whilst the instructions aim to cover as many eventualities as possible caution and common sense should be applied when operating and installing this air conditioner.
  • Page 2 GB-5751010700 15-01-2004 16:33 Pagina 17 How does your Pinguino work uring the summer, optimum comfort is achieved with a temperature of around 24 °C and 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located. One advantage of portable air conditioning units over fitted models is that they can be moved from one room to another in the home or even transferred between different buildings.
  • Page 3 GB-5751010700 15-01-2004 16:33 Pagina 18 S e t t i n g u p The following instructions will help you set up your air conditioning unit as efficiently as possible. • With a double casement window, use the AIR CONDITIONING WITHOUT INSTALLATION suckers provided to hold the two hal- FOR INSTANT TEMPORARY USAGE...
  • Page 4 GB-5751010700 15-01-2004 16:33 Pagina 19 S e t t i n g u p AIR CONDITIONING WITH INSTALLATION • Fit the flange supplied to the hole. For more efficient use Pinguino can also be • Fix the hose to the coupling on the semi-permanently installed back of the unit (figure A).
  • Page 5 GB-5751010700 15-01-2004 16:33 Pagina 20 Pre p a ra t i o n f o r u s e HOW TO USE THE AIRCONDITIONER WITH WATER These air conditioners can use both air and water to cool the condenser (the hot part) of the air conditioner.
  • Page 6: Setting The Timer

    GB-5751010700 15-01-2004 16:33 Pagina 21 Setting the timer PROGRAMMED MODE ELECTRICAL CONNECTION 1) Set the operating times by pushing out the Before plugging in check that: notches on the dial corresponding to the • the mains supply corresponds to the period required (each notch represents 15 power supply shown on the rating plate;...
  • Page 7 GB-5751010700 15-01-2004 16:33 Pagina 22 Turning on and Selecting functions AIR CONDITIONING FUNCTIONS Delay on Start Up To turn the unit on in air conditioning mode, 1. A special safety device will delay the start of air conditionig by approximately 3 to 5 proceed as follows: minutes when switching between func- 1.
  • Page 8 GB-5751010700 15-01-2004 16:33 Pagina 23 R e c o m m e n d a t i o n s RECOMMENDATIONS • Make sure there are no heat sources in the room. Follow these recommendations to achieve maximum efficiency from your air conditio- •...
  • Page 9 GB-5751010700 15-01-2004 16:33 Pagina 24 M a i n t e n a n c e Before cleaning or maintaining the unit, always CLEANING THE RESORVOIR turn the unit off by releasing the button It is recommended that you clean this at least and unplug from the mains .
  • Page 10 GB-5751010700 15-01-2004 16:33 Pagina 25 De s c a l i n g When the scale deposits become excessive (on average, after about 400 hours of opera- tion) or in any case, at least once each sea- son, it is very important to proceed with the decalcification of the appliance as described below.
  • Page 11: Troubleshooting

    GB-5751010700 15-01-2004 16:33 Pagina 26 Troubleshooting If the unit is not working properly, this may be due to small problems that you can easily resolve yourself. Follow these instructions carefully before contacting your local Authorised Technical Service Centre. PROBLEM CAUSE REMEDY •...
  • Page 12: Technical Specification

    GB-5751010700 15-01-2004 16:33 Pagina 27 Technical specification TECHNICAL SPECIFICATION RECOMMENDED OPERATING CONDITIONS Power supply see rating plate WHEN CONDITIONING Max. absorbed power Room temperature 21 ÷ 32°C in air conditioning “ Refrigerating capacity “ Refrigerant “ Max. absorbed power when heating “...

Table of Contents