3.2.4 Installing the Controller

The ePump can be operated by one of three
(3) controllers: the ePump controller (JEP-R), the
AquaLink® RS controller (Rev O or later), or the
AquaLink® PDA (Rev 4.0 or later).
The ePump communicates with the controllers via a
four-wire RS-485 interface.
To install the ePump controller:
NOTE The ePump controller part no. is JEP-R.
1.
Remove power from the ePump by disconnecting
the high voltage lines or by opening any breaker to
which the ePump power is connected.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in
the ePump electrical circuit before starting the
procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
2.
Remove the cover of the ePump junction box and
feed the RS-485 cable into the fitting.
3.
Unplug the RS-485 connector from the ePump.
4.
Attach the four (4) wires in the RS-485 cable to
the RS-485 connector. Match the wire colors with
the positions on the connector: 1- red, 2- black,
3- yellow, and 4- green. See Figure 2.
5.
Insert the RS-485 connector back into the ePump.
2 3 4
1
4-Position DIP Switch
Figure 2.
Wiring ePump Controller (JEP-R) to ePump
ePump
Series Pumps, Installation and Operation Manual
ePump Controller (JEP-R)
(Rear View)
5 4 3 2 1
4 3 2 1
RS485
REMOTE CONTROL
Jandy ePump
(Rear View)
6.
Slide dip switches 1 and 2 up, so they are in the
ON position, and slide switches 3 and 4 down, so
they are in the OFF position. See Figure 2.
7.
Connect the other end of the cable to the
controller. Match the colors of the wires with the
appropriate connector positions, as described in
Step 4.
8.
Restore power to the ePump and verify the
operation of the controller.
9.
Refer to the ePump Controller Owner's Manual,
H0311200, to operate the pump.
To install an AquaLink
later) or an AquaLink
®
1.
Remove power from the ePump by disconnecting
the high voltage lines or by opening any breaker to
which the ePump power is connected.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in
the ePump electrical circuit before starting the
procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
AquaLink
RS-485 Connectors
S1
S2
2 3 4
1
4-Position DIP Switch
Figure 3.
Wiring AquaLink
AquaLink
PDA to ePump
®
Page 11
®
RS controller (Rev O or
PDA (Rev 4.0 or later):
®
RS
4 3 2 1
4 3 2 1
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
RS6 & RS8 ONLY
RS8 ONLY
POOL MODE
RESET
SPA MODE
AUTO
SPA DRAIN
SERVICE
HEATER
SOLAR
SPA FILL
TIME OUT
Connect to
AquaLink
RS
®
RS-485 Connector
(or Multiplexer
4 3 2 1
Interface Board)
Jandy ePump
(Rear View)
®
RS Controller or

Hide quick links: