Eternal ECHNK01 Installation & Operation Manual

Condensate neutralizer kit

Advertisement

Installation ● Operation Manual
Condensate Neutralizer Kit
Item Number ECHNK01
Call us first if you have any questions with this product. We can help you with questions about assembly and
operation or if there are any damaged or missing parts when you unpack this part from the shipping box.
Please call before returning.
● Only specially trained and authorized personnel are permitted to service this product.
NOTE TO ASSEMBLER/INSTALLER:
Leave this manual with the consumer.
NOTE TO CONSUMER:
Keep this manual for future reference.
!
Turn off the electrical supply, the manual gas control valve, and the manual water control valve before installing
or servicing.
Service Information Center:
1-866-946-1096
7am-7pm CST, Monday through Friday
IMPORTANT:
WARNING
1
!
Date 2010/02/19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECHNK01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eternal ECHNK01

  • Page 1 Installation ● Operation Manual Condensate Neutralizer Kit Item Number ECHNK01 Service Information Center: Call us first if you have any questions with this product. We can help you with questions about assembly and operation or if there are any damaged or missing parts when you unpack this part from the shipping box.
  • Page 2 The Eternal Condensate Neutralizer Kit increases pH (reduces acidity) The Eternal Condensate Neutralizer Kit is designed to raise the pH level of the condensate discharged by the Eternal Water Heater. Each change of 1.0 in pH is a 10-times reduction or (increase) in concentration. The pH of condensate is increased by approximately 1.0 to 3.0 higher after passing through the Condensate Neutralizer Kit.
  • Page 3 Parts List and Diagram Left Description PVC Tubing filled with 1/2'' and 3/4'' Aggregate Calcium Carbonate Channel Strut Mounts Galvanized Strut Clamps, Bolts, and Nuts Condensate Outlet Hose Barb Fitting Condensate Inlet Hose Barb Fitting Plugged-Alternate Location for Condensate Inlet Hose Barb Fitting Note: Hose Barb Fittings to 30'.
  • Page 4 Installation and Maintenance Intake Air Exhaust Relief Valve Discharge Line Eternal Condensate Neutralizer Condensate Hose Drain Tap with mesh filter Adapter Sediment Trap (These diagrams are for reference as basic guides. Each installation should be engineered properly and compliant to Local, State, and Federal Codes.) Installation Instructions: Securely fasten the two bases to floor or wall.
  • Page 5 Installation and Maintenance WARNING ● Apply to flue gas condensing water heater and breeching condensate drains only. ● DO NOT exhaust flue gases through the Neutralizer Kit. It is not rated for water heater flue gases. Operating the Neutralizer Kit as an exhaust vent can cause injury or death from carbon monoxide. ●...