Sanyo XHX1252 Instruction Manual page 5

Split system air conditioner
Hide thumbs Also See for XHX1252:
Table of Contents

Advertisement

G: ADDRESS button
NOTE
H: A/C SENSOR button
NOTE
I:
FLAP button
NOTE
(SWEEP)
NOTE
J: TIMER SET button
(OFF Timer)
(OFF Cycle Timer)
(ON Timer)
OI-837-5-EG
Parts Name and Functions (continued)
When a multiple number of indoor units that can be operated by the wireless remote control
unit have been installed in the same room with a multi-unit or single-unit installation, this
button enables addresses to be set in order to prevent the sending of signals to the wrong
indoor unit. Each of up to six indoor units can be controlled separately using its own wireless
remote control unit by matching the number of the address switch on the operation area of the
indoor unit and the number used for the address of its remote control unit. (The indoor units
cannot be controlled separately when they are used in a flexible combination format,
simultaneous operation of multi units format or any other such format since they will all
operate at the same time.)
When the batteries are replaced, the address setting returns to "ALL", and so please make the
setting again.
When you press this button (use a small-tipped object such as a ballpoint pen), the
indication will disappear at the display. And the room temperature is detected by the sensor
which is built in the indoor unit and the air conditioner is controlled accordingly.
If the remote control is located near a heat source, such as a space heater or in direct
sunlight, press the A/C SENSOR button to switch to the sensor on the indoor unit.
1. Use this button to set the airflow direction to a specific angle.
The airflow direction is displayed on the remote control unit.
Operation mode
(COOL) or
(DRY)
(HEAT) or
(FAN)
(AUTO)
Cooling mode:
Heating mode:
In the cool mode and dry mode, if the flaps are set in a downward position,
condensation may form and drip around the vent.
Do not move the flap with your hands.
This function is available only for models X, A, T and K.
2. Use this button to make the airflow direction sweep up and down automatically.
Press this button several times until the
To stop the swing operation
Press the FLAP button again during the flap swing operation to stop the flap at the desired
position. Then, the airflow can be set from the top position by pressing the FLAP button again.
Indicator when swing operation is stopped
Fan and heating
During cooling and drying, the flap does not stop at the downward position. Even if the flap is
stopped at the downward position during the swing operation, it does not stop until it moves to
the third position from the top.
This function is available only for models X, A, T and K.
Use this button while the unit is operating to switch between timer settings.
:
The air conditioner stops after a preset time elapses.
:The air conditioner always stops after a preset time elapses.
:
The air conditioner starts after a preset time elapses.
Number of airflow direction settings
3
5
3
5
symbol appears on the display.
Cooling and drying
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents