Jandy FHPM FloPro Series Installation And Operation Manual page 9

Table of Contents

Advertisement

3.1.3 Replacement of Existing Pump
Jandy FHP pumps can easily replace several
other pumps: the Hayward
SuperFlo
, Pentair
WhisperFlo
®
®
and Jandy MaxHP (MHP).
To replace the Pentair
or Jandy MHP, use the FHP's adjustable base. The FHP
base (and its spacers) increase the total height of the
pump and the height of the suction side of the pump.
See Table 1.
Table 1. FHP Dimensions
Base Configuration
Pump without Base
Pump with Base
Pump with Base and Spacers
3.1.3.1
Hayward
®
Pentair
SuperFlo
®
The Jandy FHP can replace a Hayward
Pump
or a Pentair
SuperFlo
®
®
base. See Figure 2.
12 3/4"
7 3/4"
Figure 2.
Place FHP Directly on Equipment Pad
3.1.3.2
Pentair
WhisperFlo
®
To replace a Pentair
®
Jandy FHP, place the FHP base on the equipment pad
and place the FHP on the base, as shown in Figure 3.
13 7/8"
8 7/8"
Figure 3.
Place FHP with Base on Equipment Pad
Hayward and Super Pump are registered trademarks of Hayward
Industries, Inc.
Pentair is a registered trademark of Pentair, Inc.
SuperFlo and WhisperFlo are registered trademarks of Pentair Water
Pool and Spa, Inc.
FloPro Series Pumps Installation and Operation Manual
Super Pump
, Pentair
®
®
®
, Jandy PlusHP (PHP),
®
WhisperFlo
, Jandy PHP,
®
®
Suction Side
Pump
Height
Height
7 ¾"
12¾"
8⅞"
13⅞"
9⅛"
14⅛"
Super Pump
and
®
®
®
Super
without using the FHP
®
Pump
®
WhisperFlo
pump with a
®
3.1.3.3
Jandy PlusHP (PHP) and
Jandy MaxHP (MHP)
To replace a Jandy PHP or Jandy MHP pump with a
Jandy FHP, use the FHP base with spacers.
1.
Using a hand cutter tool, cut the plastic bars
connecting the top and bottom sets of spacers, as
shown in Figure 4.
2.
Push the two (2) top spacers and two (2) bottom
spacers out of the base.
3.
Align the pins in the four (4) spacers with the
holes in the base and snap the spacers into place,
as shown in Figure 5.
4.
Place the FHP on the base assembly. See Figure 6.
Cut
spacers
at X.
Figure 4.
Cut Sets of Spacers Out of Base
Figure 5.
Snap Spacers into Place
14 1/8"
9 1/8"
Figure 6.
Place FHP with Base and Spacers on
Equipment Pad
Page 9
X
X

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Jandy FHPM FloPro Series