Rejection
=
=
=
Passage
=
=
=
Recovery
=
=
=
4
[(C
) - (C
)] x 100
avg
P
(C
)
avg
[(237.5 mg/L) + (8.3 mg/L)] x 100
(237.5)
96.5%
(C
) x 100
P
(C
)
f
(8.3 mg/L) x 100
(237.5)
3.5%
(Q
) x 100
P
(Q
)
f
(18 gpm) x 100
(24gpm)
75%